My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:56:31 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W RCB, January 2002 <br />C <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Page 5 of 5 <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested 0 <br />Test Method Developed by <br />❑ Sump Manufacturer 0 Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used <br />❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />T :st Equipment Used: Incon TS -STS Equipment Resolution: .0006 <br />Fill Sump # <br />UE046UO02 <br />Fill Sump # <br />Fill Sump # <br />Flu Sump # <br />Summa Diameter: <br />44" <br />Sum Depth: <br />80" <br />i 0iz,ht from Tank Top to Top of <br />I Iighest Piping Penetration: <br />32" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />31" <br />Condition of sump prior to testing: <br />Good <br />Portion of Sump Tested: <br />2" above high pen <br />Sump Material: <br />Poly <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 min <br />Test Start Time: <br />10:09 am 10:25 am <br />Initial Reading R.i): <br />3.4926 3.4944 <br />Test End Time: <br />10:24 am 10:40 am <br />Finai Reading (Rf): <br />3.4943 3.4943 <br />Test Duration: <br />15 min 15 min <br />_ <br />W <br />Chane in Reading Rf-Ri : <br />.0017 .0001 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />Test Result: <br />2 Pass ❑ Fail <br />❑ Pass ❑ Fall <br />❑ Paw ❑ Fall <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />Does the sensor alarm when either <br />product or water is detected? <br />[] Yes ® No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />CJ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ® No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />and <br />Sensor reinstalled to lowest point but not tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.