My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Feb -26. 2013 10:29AM RUMEX CONSTRUCTION <br />SWRCB, January 2002 0 <br />4. TANK ANNULAR TESTING <br />No. 8254 P. 3 <br />0 page — <br />In <br />Test Method Developed By: <br />0 Tank Manufacturer D Industry Standard 0 Professional )Engineer <br />0 Other (Specify) <br />Test Method Used, <br />D Pressure <br />13 Other (Specify) <br />D Industry Standard D Hydrostatic <br />Test Equipment Used: Vacuum Gauges <br />Tank 0 87 <br />Is Tank Exempt From Testing?' 0 Yes X NO <br />Equipment Resolution: 0,5% of dial <br />11 111� <br />Tank# Took # Tank # <br />0 Yes D No 0 Yes 0 No 0 Yes 0 NO <br />Tank Capacity: <br />12000 <br />Tank Material: <br />Metal Fiberglass <br />Tank Manufacturer: <br />Joor <br />Product Stored: <br />181 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 minutes <br />30 minutes 30 minutes 30 minutes <br />Test Start Time: <br />loam <br />Initial Reading (111): <br />1044 <br />10" 1011 10" <br />Test End Time: <br />1 lam <br />Final Reading (RF): <br />lot$ <br />Test Duration; <br />I Hour <br />I Hour I Hour I Hour <br />Change in Reading (RF-Ro-, <br />0 <br />Pass/Fail Threshold or Criteria: <br />0 <br />0 0 0 <br />Test Result -'; <br />X Pass. Oran <br />0 Pass 11 Fail 1i Pam 0 "il 0 Pass,.,O Fall <br />Was sensor removed for testing? <br />XYes 0 No 0 NA <br />DYes DNo [DNA DYes ONo DNA 0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after les ' ? <br />X Yes 0 No 0 NA <br />OYes DNo DNA 0 Yes 0 No 0 NA DYes MNo DNA <br />- Comments — (include information on repairs made prior to testing, and recommended follow-upfor failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.