My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Feb. 6. 2012 8:33AM RUM CONSTRUCTION No, 1140 P. 2/6 <br />NI N SYSTEM CE TI IION <br />For Use By All Jurisdictions 97th in the State of California <br />Authopiry Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, 71tde 23, California Code ofAdgulations <br />This form must be used to document testing and servicing of monitoring equipment. A se crate certification or report must r each <br />monitoring system control panel by the technician who performs the work. A copy of this farm must be provided to the tank cystt�+p <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. t <br />A. General Information <br />Facility Name: STOCKTON CHP Bldg. No.: <br />Site Address: 3330 N. AD ART RD. City: STOCKTON Zip: 95215 <br />Facility Contact person: JIM MURRAY <br />Make/Model of Monitoring System: V/R TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Contact Phone No.: (2209) 943-8666 <br />Date of Testing/Servicing: 1/30/2012 <br />Tank ID: 87 <br />® In -Tank Gauging Probe. Model: V/R <br />Annular Space or Vault Sensor. Model; V/R 420 <br />® Piping Sump / Trench Sensor(s). Model; V/R 208 <br />® Fill Sump Sensor(s). Model: V/R 208 <br />® Mechanical Line Leak Detector, Model; FE PETRO <br />❑ Electronic Line Leak Detector. Model: <br />® Tank Overfill / High-'Levcl Sensor, Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank 1D: <br />❑ In -Tank Gauging Probe. Model: <br />Annular Space or Vault Sensor. Model: <br />❑ Piping Sump / Trench Sensor(s), Model; <br />❑ Fill Sump Sensor(s). Model: <br />❑ Mechanical Line Leak Detector, Model: <br />❑ Electronic Line Loak Detector, Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank 10D: <br />T'ank 1D: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector_ <br />Model: <br />❑ Mechanical line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector, <br />Model; <br />❑ Tank Overfill / High -Level Seer, <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model; _ <br />❑ Other (specify equipment type and model in Section B on Pago 2), <br />❑ Other (specify equipment we and model in Section E on Page 2). <br />Dispenser ID: 112; <br />Dispenser 11D: <br />® Dispenser Containment Sonsor(s), <br />Model: V/R 208 <br />❑ DispenserContainmcnt Senmr(s). <br />Model: <br />® Shear Valvo(s). <br />❑ Shcar Valvc(s), <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser 11): <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s)• <br />Model: <br />❑ Dispenser Containment Sensor(%). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valvc(s), <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser 111): <br />Dispenser 1D: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shur V'alve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility, <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Platy showing the layout of monitoring equipment. For any equipment capable of generati reports, I have also <br />attached a copy of the report; (check all that apply): System set-up ® Alarm hl rt. - <br />Technician Name (print), Phillip Mendrin Signature: <br />Certification No.: 5252185 -UT License, No,•� 72234 <br />14-1 <br />Testing Company Name: Ramex Construction Corp Phone No.: (559) 271-3300 <br />Testing Company Address: 4670 N. Bendel Ave. Fresno CA 93722 Date of Testing/Servicing: 1/30/2012 <br />Page 1 of 3 <br />Rev (2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.