COMPLIANCE INFO_2003-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2003-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
6/23/2020 6:53:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2011
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231911_14971 N HWY 88_2003-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ONVIRONMENTAL HEALTH DEPARTMENT. <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smgov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> Country Side Mini Mart 14971 N Hwy 88 Lodi, Ca 95240 5/17/2010 <br /> # Code Section VIOHSC=CA Health&SafetyCode; CCR=CAC Code of Regulations;V=Violation; RV=Re eat Violation ONS V V <br /> Designated operator monthly inspection: (c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (d), UDCs,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted; (c)(6) x <br /> (e) employee training not verified;(d)(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed;(2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, x <br /> repair,replacement,calibration,or certification;(f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified, repaired,or replaced <br /> 25 HSC 25291(f) Annual line leak detector test not performed (M1) x <br /> 26 HSC 25284.2 Annual spill containment testing not performed x <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 28 CCR 2661(f) Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed pre-Janus 1, 1984) (M1) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-Janus 1, 1984) (M1) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(a)(9) Tam e ing with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636(P(6)=Emergency generator monitoring system not checked daily or log not kept (M1) <br /> 41 HSC 25281.5(b)(3) I Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br /> VPH Systems HSC 25290.2(installed between 07/01/03 and 06/30/04) HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored; (b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and(d)for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(p)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the <br /> HSC 25290.2(d) entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space <br /> of the UST system not maintained <br /> HSC 25290.1 Q) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection; (2) <br /> 48 HSC 25290.2(i) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> EHD inspector: Ns cacapit 7 Phone: UIC Septic system: <br /> (209) 468-3453 ❑Serves 20 people/day <br /> Received by Tim: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> ❑Dry wells/French Drains <br /> E - 02 REV 04/08/10 Page 2 UST OFFICIAL INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.