My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2003-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
6/23/2020 6:53:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2011
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231911_14971 N HWY 88_2003-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
04/05/2010 10:17 209-465-4988 HMC PAGE 02/05 <br /> SWRCB,January 2002 Page_of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 0 Tank Manufacturer X Industry Standard C..1 Professional Engineer <br /> f-1 Other fSpeeiA,) <br /> Test Method lJsed ��1-11 Pressure X Vacuum D Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used:VACUUM Equipment Resolution:"WC <br /> T <br /> ,10- Ogg 71 <br /> Tank#87/91/DSL Tank# Tank# Tank A <br /> is Tank Exempt From.Testing?( [J Yes KNo !D Yes 0 No 0 Yes I."]No 0 Yes 0 No <br /> Tank Capacity: 20K <br /> Tank Material: STEEL. <br /> Tank Manufacturer. UNKNOWN <br /> Product Stored: FUEL <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> stard!!&test,----- <br /> Test Start Time: 0946 <br /> Initial Reading(Ri)-. 7" <br /> Test End Time: 1046 <br /> Final Reading(Rj): 6.5" <br /> Test Duration: I HR <br /> Change in Reading(RF-R-1): 0,51, <br /> Pass/rail Threshold or Criteria: 2" <br /> Test Result: X Pass 0 Fail 0 Pass, 0 Fail 0 Pass 0 Fall 0 Pass 0 Fail <br /> Was sensor removed for testing? XYes ONo CNA DYes LNo (DNA OYes CNo 'DINA DYes ONO DNA <br /> Was sensor properly replaced and <br /> verified functional after testi OYes CI Na CN]A. rJYes U-No DNA 0 NA OYes C1 No ClNAComments—(irwdude fn orrsafian on repairs made ritx io testing,and recommended ollow-!Lpfar faaled wiv) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.