My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 1:53:18 PM
Creation date
6/23/2020 6:53:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19255517888 Main Fax GETTLER RYAN INC 8:34 p.m. 04-23-2008 8112 <br /> For EMV models <br /> a. Remove 1/4-inch pipe plug from tank test port in the ® if flow is restricted to about 3 gpm(11 ipm)or less <br /> Packer (on 6-inch Big-Flo applications, remove the with the nozzle open, the leak detector has not <br /> 1/4-inch pipe plug from the riser/flange assembly). opened. Repeat step Sa with increased running <br /> b. Apply a UL-classified non-toxic pipe thread sealant to time of pump to insurethe purging of all air.All air <br /> the 1/4-inch NPT 45-degree elbow and install in tank must be purged from the system or the leak <br /> test port of the packer. On 6-inch Big-Flo applications, detector will restrict flow to about 3 gpm(11 1pm). <br /> the 1/4-inch NPT 45-degree elbow may be installed 9. Affix the enclosed decals to the dispenser dial glass on grade <br /> into the riser/flange assembly. of gasoline upon which the leak detector is being installed. <br /> c. Apply UL-classified non-toxic pipe thread sealant to Additional decals are available; call customer service at <br /> the 1/4-inch NPT hex nipple and install on 45-degree 1-800-262-7539. <br /> elbow that is in the tank test port(or on 6 inch Big-Flo 10. Inspect all threaded joints to assure they are tight and not <br /> riser/flange assembly. leaking. <br /> d. Apply a UL-classified non-toxic pipe thread sealant to <br /> the 1/4-inch NPT tee and install on the hex nipple to Test of the Leak Detector <br /> accommodate both the vent tube and the snap tap. U.S. Environmental Protection Agency (EPA) regulations require <br /> e. Apply a UL-classified non-toxic pipe thread sealant to <br /> the threads of the 1/4-inch NPT 90-degree elbow vent annual verification of operation of leak detector. To assure <br /> tube fitting and install in the tee. maintenance of leak detection capability, Red Jacket requires that <br /> UL-classified non-toxic pipe thread sealant to operation of the mechanical leak detector be verified by testing upon <br /> f. Apply a UL- start-up and that testing of the leak detector be performed routinely at <br /> the threads cl the 1/4-inch NPT straight vent tube <br /> least annually. <br /> fitting and install in the leak detector vent opening in <br /> the cap of the leak detector. <br /> g. Install the vent tubing into both fittings and tighten per s Test procedure options for mechanical leak <br /> instructions on package. detectors are explained in Red Jacket Engineering <br /> P $ Reports,RJ20 and RJ21.The Red Jacket Snap Tap <br /> h. To install snap tap connectors in FX2V/FX2DV Connectors allow the FX2V/FX2DV leak detector <br /> models, apply a UL-classified non-toxic pipe thread to be tested with the FXV Snap Tap Tester as an <br /> sealant to the snap tap connectors and install one in the option to the above test methods.See Red Jacket <br /> body of the FXV leak detector and the other in the tee literature #042-111-1 for test instructions using <br /> attached to the hex nipple attached to the 45-degree Snap Tap Connectom <br /> elbow installed in the tank test port of the packer.On 6- 11. The top cover on the Red Jacket leak detector is designed to <br /> inch Big-Flo applications, install the two snap tap accommodate a sealing wire which can be used to <br /> connectors-one in the body of the FXV leak detector discourage tampering or the unauthorized removal of leak <br /> and one in the riser/flange assembly. detector.(See Figure 2). <br /> i. Attach and crimp loop of the retaining tether <br /> around the Snap Tap threads. ® It should be noted that if the dispensing system(the <br /> j. Replace the caps over the quick-connect couplings and solenoid valve and the nozzle)is opened previous to <br /> tighten snugly. the completion of the line test,the FXV Series will <br /> detect this opening as a leak and restricted flow <br /> DO NOT overtighlen. will result. Closing of the nozzle(s)for a period of <br /> time adequate to allow completion of the line test <br /> ® See technical bulletin#042-111-1 for use of Snap will allow the leak detector to open.Once opened, <br /> Tap Connector Assembly. full pump flow can be provided. <br /> 7. Connect power to pump at the load center. <br /> 8. Clear remaining air from system as follows: <br /> a. Tum on dispenser that is farthest from the leak detector <br /> but do not open nozzle.Wait 4 or 5 minutes or more. <br /> Look for leaks on parts worked on. <br /> b. Shut off the pump and allow it to stand four or five <br /> minutes. Then start the pump again and open the FX2V/FX2DVJ OL TETHERED <br /> nozzle farthest from the leak detector. CAP <br /> c. Continue to dispense enough gasoline,about 20 to 30 <br /> gallons(76 to 114 liters), to pump ALL air from the <br /> system. SNAP TAP 45°ELBOW <br /> Figure 1 <br /> a o , <br /> O o <br /> SEALING WIREi t 114-INCH <br /> •1 <br /> (provided by contractor) QI T-FITTING <br /> (o <br /> VENTTLIBE <br /> Figure 2 �'J <br />
The URL can be used to link to this page
Your browser does not support the video tag.