n <br />U <br />SWRCB, January 2002 <br />9< nirprnrc12 crrnp TRcTyNfl- <br />Page ( of <br />Test Method Developed By: 0 Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: 0 Pressure ❑ Vacuum 0 hydrostatic <br />0 Other (Spec) <br />Test Equipment Used. ELLDS ! <br />Equipment Resolutmn:.0007 <br />Sump # . o'7-1 <br />Sump # 7 7. <br />Sump # <br />Sump # <br />Sump Diameter. '' <br />y ° ` <br />Sump Depth: ,g '' <br />Sump Material• <br />Height from Tank Top to Top of <br />Highest NOM Penetration: , <br />17 <br />Height from Tank Top to Lowest „ <br />Electrical Penetration: <br />, • <br />.. <br />Condition of sump prior to testing: g>� <br />Portion of Sump Tested' 2" above highest <br />penetration <br />2" above highest <br />etration <br />2" above highest <br />penetration <br />2" above highest <br />venetration <br />Does turbine shut down when <br />sump sensor detects liquid (both ❑ Yes ❑ No e A <br />product and water)9' <br />❑ Yes ❑ No. ff'1�A <br />❑ Yes ❑ No fflA <br />0 Yes ONO ❑ NA <br />Turbine shutdown response time N/A <br />N/A <br />N/A <br />N/A <br />IS system programmed for fail-safe <br />shutdown? 0 Yes 11No ff9A <br />❑ Yes ❑ No D< <br />0 Yes ❑ No 59A <br />0 Yes 0 No [INA <br />Was fail-safe verified to be ❑ Yes ❑ No B16 <br />o erational?° <br />0 Yes ❑ No Did <br />0 Yes ❑ No B11M <br />❑ Yes ❑ No ❑ NA <br />Wait time between applying <br />pressurely water and starting 30 minutes <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: t/ <br />2 13 : r <br />z , 3 <br />Initial Reading W: <br />4 V. z S 70 <br />Z'i'6 t y 2N.5 <br />Test End Time: <br />1:07 <br />1 Z g'7 t o 7 <br />Final Reading (RF): <br />5 D <br />V Z X6 YY. Z'Yet <br />Test Duration: 15 m <br />nutes <br />15 Utes <br />15 m. nutes <br />15 minutes <br />Change in Reading (R R�}: <br />Pass/Fail Threshold or Criteria: 0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />Test Result; ❑ Pass 0 Fail <br />APass 0 Pail <br />MPass 0 Fail <br />❑ Pass 0 fail <br />Was sensor removed for testing? I?XYes ❑ No DNA <br />AYes ONO ❑ NA <br />9yes 0 No 0 NA <br />Oyes ONO [INA <br />Was sensor properly replaced and Ryes ❑ No DNA <br />verified fimcdonal after testing? <br />XYes ❑ No [INA <br />Yes 0 No DNA <br />0 Yes ❑ No 0 NA <br />Comments — rnclude information on repairs made prior to tesEiM and recommended follow-up for failed tests) <br />y _ r <br />Arco #05450 <br />1617 W. Fremont <br />Stockton, Ca <br />Nick Harvey <br /># 10073 SB 989 <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />