COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date 8/5/14 21 <br />Test Information <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak test detector test pass/fail is determined using a low <br />flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Gettler--Ryan Inc. <br />Technician Chris San Nicolas Lic# <br />Signature <br />j <br />2 <br />3 <br />4 <br />5 <br />Product <br />7 <br />91 <br />Manufacturer <br />VR <br />V <br />Model <br />848480 <br />848480 <br />Full Operating Pressure (psi) <br />36 <br />30 <br />Line Bleed Back (l) <br />INA <br />NA <br />Trip Time (sec) <br />NA <br />NA <br />Mete -ring Pressure (psi) <br />NA <br />NA <br />RE Holding Pressure (psi) <br />25 <br />22 <br />Test Leak Rate (ml/min)(gph) <br />189ml <br />189ml <br />PASS or FAIL <br />P <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak test detector test pass/fail is determined using a low <br />flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Gettler--Ryan Inc. <br />Technician Chris San Nicolas Lic# <br />Signature <br />
The URL can be used to link to this page
Your browser does not support the video tag.