PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> SWRCB,January 2002 Page-3—of 3 <br /> 5. UNDER-DISPENSER CONTAIN] C)TESTING <br /> Test Method Developed By: 0 UDC Manufacturer x Industry Standard 0 Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 11 Pressure El Vacuum x Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used:Incon is-sts Equipment Resolution:.00 I" <br /> UDC#1-2 UDC#34 UDC#5-6 Sat UDC#6-7 <br /> C Manufacture?: Bravo <br /> UDC Material: Steel <br /> UDC D9 <br /> the 12" <br /> Height from UDC Bottom to Top Ol <br /> of Highest Pi in Penetration: MAR 112 16 <br /> Height from UDC Bottom to 071 <br /> Lowest Electrical Penetration: ENVIBONM MAL <br /> Condition of UDC prior to Clean HEALTH DEPAR11MENT <br /> testing: <br /> Portion of UDC Tested' 1/2 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 0 Yes ONo XNA 0 Yes 0 No NA 0 Yes D No NA 0 Yes 0 No NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown?* 0 Yes ONo XNA 0 Yes 0 N1 NA 0 Yes 0 No NA 0 Yes 0 No NA <br /> Was fail-safe verified to be 0 Yes ONo XNA 0 Yes 0 Nc NA 0 Yes 0 No NA 0 Yes 0 No NA <br /> operational?* <br /> Wait time between applying 15 min. 15 min. <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 4:08 <br /> Initial Reading(Li): 4.539 <br /> Test End Time: 4:23 <br /> Final Reading(RF): 4.538 <br /> Test Duration: 15 Min. <br /> Change in Reading(RF-Ri): 0.001 <br /> Pass/Fail Threshold or Criteria: 0.002 <br /> T` sltid Q Fail <br /> Was sensor removed for testing? 0 Yes ONo ONA 0 Yes 0 No X NA 0 Yes 0 No X NA 0 Yes 0 No XNA <br /> Was sensor properly replaced and 11 Yes El No El NA OYes ONo JXNA 0 Yes 0 No X NA 0 Yes 0 No XNA <br /> verified functional after testinc-- <br /> Comments— include information on repairs madeFWor to Cestang; and ecommended ollaw-u oraided tests) <br /> Tightened entry fittim. <br /> If the entire depth of the UDC is not tested,specify how much was tested. Ilf the answer to M of the questions indicated with an <br /> asterisk(*)is"NU'or"NA",the entire UDC must be tested. (See SWRCB11 LG-160) <br />