My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1465
>
2300 - Underground Storage Tank Program
>
PR0232272
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:28 AM
Creation date
6/23/2020 6:54:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0232272
PE
2361
FACILITY_ID
FA0003925
FACILITY_NAME
COS MUNICIPAL SERVICE CTR
STREET_NUMBER
1465
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1941
APN
16504015
CURRENT_STATUS
01
SITE_LOCATION
1465 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232272_1465 S LINCOLN_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page.___,of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer i7 Industry Standard ❑Professional Engineer <br /> U Other(Speaj&) <br /> Test Method Used: U Pressure U Vacuum ❑Hydrostatic <br /> IJ Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank#1 Tank#2 Tank# Tank# <br /> Is Tank Exempt From Testing? *Yes *Yes <br /> Tank Capacity: 12k l2k <br /> Tank Material: Fiberglass Fiberglass <br /> Tank Manufacturer: XERXES XERXES <br /> Product Stored: Diesel Gas <br /> Wait time between applying *Exempt *Exempt <br /> vacuum and starting test: See comments See comments <br /> Test Start Time: <br /> Initial Reading(RI): <br /> Test End Time: <br /> Final Reading(Rr,): <br /> Test Duration: <br /> Change in Reading(%-Ra): <br /> Pass/Fail Threshold tor Criteria: <br /> Test Result:. <br /> Was sensor removed for testing? <br /> Was sensor properly replaced and <br /> verifaed functional after testing? <br /> Comrn ents—(include information on repairs made prior to testf�,and recommended(follow-up for failed tests) <br /> *Tanks have Brine Wed Annulars,and are Exempt from Periodic Testing. <br /> 'Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. f Califomia Code of Regulations,Title 23,Section 2637(ax6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.