Laserfiche WebLink
E <br />SWRCB, January 2002 - Page of <br />7. UNDER -DISPENSER CONTAINMENT (UD ESTING <br />Test Modal Developed By D UDC Manufacturer ehidustcp Standard D Professional .Engineer <br />0 Other (Spec6) <br />Test Method Used: 0 Pressure 0 Vacuum ®Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used: TS STS Equipment Rasolution: 0.0001„ <br />Comments — 0nclude information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br />All Testing Done With Inspector On Site. <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested (See SWRCB LG -160) <br />UiiC # 7-8 <br />UDC # <br />UDC # <br />UDC Manufacturer: <br />UNK <br />7 <br />UNK <br />UDC Material: <br />PLASTIC <br />PLASTIC <br />UDC Depth: <br />10" <br />10" <br />Height from UDC Bottom to Top <br />of Highest Pi in Penetration: <br />0 <br />0 <br />Height from UDC Donor to <br />Lowest Electrical Penetration <br />0 <br />0 <br />Condition of UDC prior to <br />testing: <br />GOOD <br />GOOD <br />Portion of UDC Tested <br />3" <br />4" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?k <br />0 Yes 0 No <br />0 NA <br />0 Yes 0 No O <br />NA <br />O Yes O No ❑ NA <br />0 Yes 0 No ❑ NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?' <br />O Yes O Na <br />u NA <br />0 Yes 0 No 0 <br />NA <br />Utes QNo ONA <br />-Yes QNo DNA <br />Was fail-safe verified to be <br />operational? <br />0 Yes 0 No <br />0 NA <br />0 Yes 0 No 0 <br />NA <br />0 Yes O No DNA <br />0 Yes 0 No 0 NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />0859 <br />0859 <br />Initial Reading (itr): <br />.8639 <br />1.4021 <br />Test End Time: <br />0914 <br />0914 <br />Final Reading (Rr): <br />.903 <br />1.4020 <br />Test Duration: <br />15 MIN <br />15 MIN <br />Change in Reading (RF -n: <br />.0011 <br />.0001 <br />Pass/Fail Threshold ar Criteria. <br />0.002 <br />0.002 <br />Test Result: <br />®Pass 0 Fail <br />®Pass 0 Fail <br />❑ Pass OFail <br />0 Pass OFail <br />Was sensor removed for testing? <br />®yes 0 No <br />0 NA <br />®Yes ❑ No 0 NA <br />OYes 0 No 0 NA <br />OYes 0 No 0 NA <br />Was sensor properly nepJa=l and <br />verified functional after testing? <br />®Yes O No <br />DNA <br />®Yes 0 No 0 NA <br />OYes 0 No O NA <br />OYes 0 No ❑ NA <br />Comments — 0nclude information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br />All Testing Done With Inspector On Site. <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested (See SWRCB LG -160) <br />