My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1465
>
2300 - Underground Storage Tank Program
>
PR0232272
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 2:55:45 PM
Creation date
6/23/2020 6:54:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0232272
PE
2361
FACILITY_ID
FA0003925
FACILITY_NAME
COS MUNICIPAL SERVICE CTR
STREET_NUMBER
1465
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1941
APN
16504015
CURRENT_STATUS
01
SITE_LOCATION
1465 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232272_1465 S LINCOLN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
511
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 2 of <br />Test Method level By- 0 Piping ,41anufacturer OlRdustry Standard u Prokssiona) Engineer <br />El Other (Specify) <br />Test Method Used: OPressure 0 Vacuum 0 Hydrostatic <br />07 Other (Specify) <br />Test Equipment Used: INCON TS -STS <br />Equipment Resolution: 0.0001" <br />Piping Run # dsl est <br />Piping Material: <br />FIBER <br />Piping Manufacturer: <br />UNK <br />Piping Diameter: <br />Tv <br />FLength of Piping Run: <br />30' <br />Product Stored: <br />DIESEL <br />Method and location of <br />piping -run isolation: <br />IBOOT /SUMP <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5MIN <br />Test Start Time: <br />0900 <br />Initial Reading (R,): <br />3psi <br />Test End Time: <br />1000 <br />Final Reading (RF): <br />3 psi <br />Test Duration: <br />IHR <br />Change in Reading (RF -R,): <br />0 <br />—Pass/Fail Threshold or <br />Criteria: <br />0 <br />Test Result <br />®Pass 11 Fail OPass 11 Fail 0 Pass 11 Fail 0 Pass 0 Fail <br />Comments — (include information on repairs pairs madeprior to testing, and recommended folloit,-tip,foi-,failed tests) <br />Replaced Secondary Boot on diesel east line in dispenser #7/8 and tightened bolts around fittings. Cleaned <br />and tightened bolts on fittings. In dispenser #5/6 and used sealant around electrical —penetrations. <br />---- --------- <br />-- -------- <br />
The URL can be used to link to this page
Your browser does not support the video tag.