My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1465
>
2300 - Underground Storage Tank Program
>
PR0232272
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 2:55:45 PM
Creation date
6/23/2020 6:54:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0232272
PE
2361
FACILITY_ID
FA0003925
FACILITY_NAME
COS MUNICIPAL SERVICE CTR
STREET_NUMBER
1465
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1941
APN
16504015
CURRENT_STATUS
01
SITE_LOCATION
1465 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232272_1465 S LINCOLN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
511
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWiCB, January 2002 <br />Page Z of -3 <br />Test,44cfi2od DeveJWd By: J,7 LW Manufacturer _R*x!us1z3, Standard 17 PWessional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure 0 Vacuum OHydrostatic <br />0 Other (Specifi) <br />Test Equipment Used: TS STS <br />Equipment Resolution: 0.0001" <br />Ffj DC # 7-9 UDC # <br />UDC # <br />UDC Manufacturer: <br />UNK UNK <br />UDC Material: <br />PLASTIC PLASTIC <br />UDC Depth: <br />WU 10" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />0 0 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />0 <br />0 <br />Condition of UDC prior to <br />testing: <br />GOOD <br />GOOD <br />Portion o C Tested' <br />3" <br />4" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?' <br />11 Yes [I No 11 NA <br />L1 Yes 11 No 11 <br />NA 0 Yes 11 No 0 NA E Yes 11 No 0 NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown'r <br />0 Yes 0 Na D. N & <br />0 Yes 0 No 0 DYes DN�a DNA 0 Yes D No 0 NA <br />NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes 0 No 0 NA <br />0 Yes 0 No El <br />NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time-. <br />1251 <br />1125 <br />Initial Ig (Rj): <br />.3501 <br />1.4852 <br />Test End Time: <br />1306 <br />1140 <br />Final Reading (RF): <br />.3499 <br />1.4554 <br />Test Duration: <br />15 MIN <br />15 MIN <br />Change in Reading (RF -RI): <br />.0002 <br />.0002 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />Test Result: <br />®Pass 0 Fail <br />®Pass 11 Fail 11 Pass []Fail <br />11 Pass UFail <br />Was sensor removed for testing? <br />®Yes 0 No D NA <br />®Yes El No 0 NA OYes 0 No 11 NA <br />F.Yes E No 0 NA <br />Was sensor properly xpJaccJ aW <br />verified functional after testing? <br />®yes 0 No D NA ®Yes 0 No El NA []Yes ❑ No 11 NA EYes 0 No 0 NA <br />Comments — (include information on repairs made prior to testing, and recoi7ii7ientledfollow-up for faded tests) <br />Replaced Secondary Boot on diesel east line in dispenser #7/8 and tightened bolts around fittings. Cleaned <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to py of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SA1RCB LG -160) <br />