My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 4:20:47 PM
Creation date
6/23/2020 6:55:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L] <br />SAN JOAam COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, SWddon, CaRlbrnla 91202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: .ora/eh#/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/15/11 <br />Facility Address: Quik Stop Markets Inc #152 1721 S Cherokee Ln Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />(CLAMS L CLAU& or MMIOR-Nolte b <br />On site to conduct a routine inspection and witness the monitoring system certification testing. <br />7. Maintenance record for the 8-5-10 L3 87 turbine sump sensor fuel alarm were not found on site. <br />These records shall be kept on site for at least 3 years. Immediately locate and maintain the <br />maintenance record for the 8-5-10 L3 87 turbine sump sensor fuel alarm on site and submit copies to the <br />EHD by 8-15-11. Repeat Violation. <br />13. The 91 Bravo box float and chain in the #1/2 dispenser sump failed to stop the flow of product at the <br />dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual <br />alarm or stop the flow of product at the dispenser when it detects a leak. The service technician adjusted <br />the chain and verified functionality. Repeat Violation. Corrected on site. <br />17. The 87, 89, and 91 line leak detectors failed to detect a leak when tested. All line leak detectors shall <br />be capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak <br />detectors, retested them, and they passed. Repeat Violation. Corrected on site. <br />18. The 87 spill container failed when tested. All spill containers shall have a minimum capacity of five <br />gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately <br />discontinue deposition of petroleum into this tank until the component is repaired or replaced by a <br />properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the spill <br />container can't be replaced immediately, there is a possibility that the 87 UST system may be red tagged <br />to prevent fuel inputs. Repeat Violation. <br />21. Liquid was observed in the 87 and 91 turbine sumps. If water could enter into the secondary <br />containment by precipitation or infiltration, it must be removed and disposed of properly. During the <br />inspection, the technician removed the liquid and placed it into the hazardous waste drum on site. <br />Continue to ensure that liquid from the secondary containment is removed, a hazardous waste <br />determination is made per Title 22 hazardous waste regulations, and the liquid waste is managed <br />accordingly. Continue to ensure that the sumps are maintained free of liquid. Repeat Violation. <br />Corrected on site. <br />23c. The designated operator failed to visually inspect the 87 turbine sump for leaks, water, or debris <br />during the 9-2-10 monthly inspection. During the monthly inspection, the designated operator shall <br />visually inspect all spill containers and UDC sumps, and any tank top sump that had an alarm for which <br />there is no record of a service visit. Ensure that designated operators performing monthly inspections at <br />ALL EHD STAPP 7W E ASSOCIAM WITH FAILING TO COMPLY BY 1HE ABOVE NOTED DATES WILL BE MUM AT THE CURRENT HOURLY RATE (=122). <br />CILiTY 18 SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector <br />Received W. <br />Title: <br />EHD 21-02-009 Har OSHOM0 COMM A11ON FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.