My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINDBERGH
>
5000
>
2300 - Underground Storage Tank Program
>
PR0232417
>
COMPLIANCE INFO_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 9:31:32 AM
Creation date
6/23/2020 6:55:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0232417
PE
2361
FACILITY_ID
FA0003676
FACILITY_NAME
GRUPE COMMERCIAL COMPANY HANGER #2
STREET_NUMBER
5000
Direction
S
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 S LINDBERGH ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232417_5000 S LINDBERGH_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> San Joaquin County <br /> Environmental Health Department R <br /> 1868 East Hazelton Avenue,Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.$)gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Address: Date: <br /> GRUPE COMMERCIAL COMPANY HANGER#2 15000 S LINDBERGH ST,STOCKTON December 20,2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. Beneath Tank Monitoring is Performed Using <br /> the Following Method(s),change Leak Sensor Model#to LS-01. Beneath Pipe Monitoring is Performed Using the <br /> Following Method(s),change Leak Sensor Model from LA-51 to LS-01;enter"Yes"for Leak Alarm Triggers <br /> Automatic Pump Shutdown,and"Yes"for Failure/Disconnect Triggers Pump Shutdown. Beneath Record Keeping, <br /> change"No"to"Yes"for Equipment Maintenance and Calibration Records. The monitoring plan must be uploaded <br /> to the California Environmental Reporting System(CERS). Immediately log into CERS, make the necessary <br /> changes,and submit for review by the EHD. <br /> This is a minor violation. <br /> 106 CCR 2632(d)(2)Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. The response plan must be uploaded to the <br /> California Environmental Reporting System(CERS). Immediately log into CERS, upload the completed form, and <br /> submit for review by the EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 113 CCR 2638(d)Failed to submit monitoring system certification test report within 30 days. <br /> A monitoring system certification, leak detector testing,and spill container testing were performed on December 18, <br /> 2015. A test report has not been submitted to the EHD or the California Environmental Reporting System(CERS). <br /> A copy of the test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br /> This is a minor violation. <br /> 201 CCR 2712(b)Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The Monitoring System <br /> Certification report for December 6,2013 testing was not found on site during the inspection. These records shall <br /> be maintained on site for at least three years. Monitoring records include:(1)date and time of all monitoring or <br /> sampling; (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results;(6)results of inventory readings and reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last <br /> submit copies to the EHD. �5 <br /> This is a minor violation. <br /> 205 CCR 2712(i)Failure to have an approved UST response plan available onsite. <br /> An approved UST Response Plan was not found on site during the inspection. The Response Plan must be <br /> uploaded to the California Environmental Reporting System(CERS). Immediately logg"FF"WYAL H(-=,'AJI <br /> completed form,and submit for review by the Environmental Health Department(EHD). EnsurE)P0A #NT <br /> available for inspection at any time. I <br /> i <br /> i <br /> This is a minor violation. <br /> FA0003676 PRO232417 SC001 12/20/2016 <br /> EHD 23.01 Rev.08/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br /> I <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.