Laserfiche WebLink
San Joaquin County c C <br /> Environmental Health Department �GN�GQ <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sj,oq v.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GRUPE COMMERCIAL COMPANY HANGER 42 1 5000 S LINDBERGH ST,STOCKTON December 20,2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> item# Remarks I <br /> t <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to appropriately respond to questions in the October 21,2016 and November 21, <br /> 2016 designated operator monthly inspection reports. The designated operator responded"yes"to'Each alarm for <br /> the previous month has been responded to appropriately'in the 10/21/16 Designated Operator monthly Inspection <br /> report and entered"Yes'to'Alarm history report/log for the previous month is available and has been reviewed by <br /> the Designated UST Operator in the 11121/16 Designated Operator monthly inspection reports when there is no <br /> alarm history available. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a repeat violation,Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 19, 2017. <br /> 3 <br /> Note: Mechanical line leak detector was not tested today (12/20/16)because the fuel level in the underground <br /> storage tank was very low. Maurice Liu will schedule the re-inspection within the month of December and will <br /> pay County fees for the re-inspection. <br /> Note:According to Zane Nimmo,the service technician,the manufacturer of the on-site monitoring panel (Leak <br /> Alert)has gone out of business and certification by Leak Alert is no longer available. <br /> Please be aware that as of January 1, 2014,facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS):UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> R, E C <br /> ENVIRONMENTAL. HEALTH <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSO _ d- GING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. I <br /> Received by: Date: December 20,2016 Inspector: Inspector Phone: i <br /> Printed Name and Title: VICKI MCCARTNEY,Senior RENS (209)468-9852 <br /> Maurice Liu,Vice President <br /> FA0003676 PR0232417 SC001 12/20/2016 <br /> EHD 23-01 Rev.09122/18 Page 6 of b Underground Storage Tank Program OIR I <br /> i <br /> I <br />