My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2512
>
2300 - Underground Storage Tank Program
>
PR0232418
>
COMPLIANCE INFO_2009-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:12:54 PM
Creation date
6/23/2020 6:55:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2010
RECORD_ID
PR0232418
PE
2361
FACILITY_ID
FA0004064
FACILITY_NAME
WATERLOO LIQUOR
STREET_NUMBER
2512
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14128102
CURRENT_STATUS
01
SITE_LOCATION
2512 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232418_2512 E WATERLOO_2009-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
313
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITAING SYSTEM E I N <br /> Fnr U.se By All Jurisdictions Within the State of Cali orn!a <br /> Authority Cited: Chapter 6.7, Ncadth and Safety Code; Charter.I6, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. must be nreyared for_each <br /> monitoring systcm control nancl by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. GenerallnforMSItion <br /> Facility Name: WATERLOO LIQUORS Bldg.No.: <br /> Site Address: 2512 E.WATERLOO RD City STOCKTON,CA Zip: 95205 <br /> Facility Contact Person: HENG CHEA Contact Phone No.: (209} 463-4114 <br /> Makc/Model of Monitoring System: INCON TS-S50 Date of TestinWServicing: 10/07/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appm riate boxes to Indicate itie equipment inspected/serviced: <br /> Tank TD: Unleaded Tank TD: Diesel <br /> ®in-Tank Gauging Probe. Model: LCi-2 98 ®in-Tank Gauging Probe. Model: LLO-2.96 <br /> ®Annular space or Vault Sensor. Model: ULS ®Annular space or Vault Sensor. Model: ULS <br /> 23 Piping Sump/Trench Sensor(s). Modal: ULS Piping Sump/Trench Sensor(s). Model: ULS <br /> ❑Fill Sump Scnsor(s). Model: ®Fill Sump Scnsor(s). Model: <br /> ❑Mechanical Line Leak Detector, Model: ❑Mechanical Line Leak t7ctoctor. Model: <br /> ❑Electronic Linc Leak Detector. Model: ❑81c rtronic Line Leak Detector. Modal: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment typo and model in Section E an Page 2). ❑Other(specify equipment type and model in Section B an Page 2). <br /> Tank ID: Diesel Saltie 1D: <br /> ®In-Tank Gaugins Probe. Model: LLO-2 0 ❑in-Tank Gauging ftbc. Model: <br /> Annular Space or Vault Sensor. Model: ULS ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Scnsor(s). Model: ULS ❑Piping Sump I Trench Sensor(s). Model: <br /> ❑Fill Sump Scnsor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: ❑Mechanical Linc Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic ianc Leak Detector. Model: <br /> ❑Tank Overfill/Iiigh-Lcvel Sensor. Model: ❑Tank Overfill/High-Uvel Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(speciry equipment type and model in Section E on Page Z). <br /> Dispenser iD: 1/2 Dispenser JD: <br /> ®Dispenser Containment Sensor(s). Model., ULS ❑Dispenser Containment Sensor(s), Model: <br /> Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ®Dispenses Containment Float(s)and Chain(s). <br /> Dispenser ID: 3/4 Dispenser ID: <br /> ®Dispenser Containment Sensor(s). Model ULS ❑Dispenser Containment Scnsor(s). Model: <br /> lel Shear Valve(s). ❑Shear Valve(s). <br /> [3 Dispenser Containment Fioata)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> 0 Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> CO Shear Vaivc(s). ❑Sher Valve(s). <br /> 0 Dispenser Containment noat(s)and Chain(s). ❑Dispenner Containment Float(s)and Chain(s). <br /> +Ifthe facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspect rviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g, manufacturers' chlcckll is necessary to verify that this Information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipmc t ftpable of generating such reports,i have also <br /> attached a copy of the report;(check all that gppdy)c ®System set-up history report <br /> Techttician Namc(print): JUNIOR S1NCO Signature: tT <br /> Certification No.: 122621376 Liccnse.No.: tl4147 <br /> Testing Company Name: Franzen-Hill lPhonc No.: 599 688-2977 <br /> Site Address: 1100 N.J St.Tulare 93274 Date of Tcsting/Servicing: 10/7/2009 <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.