My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 8:57:40 AM
Creation date
6/23/2020 6:56:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s]gov.org/ehd <br />Underground Storage Tank Program inspection Report <br />•ik. <br />Facility Name: <br />Facility Address: <br />Date: <br />GRANT LINE SHELL* <br />2375 W GRANT LINE RD TRACY <br />May 15 2018 <br />x, MR� QUI MANY &VlOiATtC3NS <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Tank Information forms for the [note which ones] are not current in CERS. <br />-The tank forms incorrectly state that the site has a vent sump. <br />-The vent piping and vapor recovery piping are marked as having secondary containment. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EHD. <br />This is a Class II violation. <br />105 <br />CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. <br />-The monitoring plans for all four tanks states the monitoring panel is a TLS -350. The monitoring panel is a Simplicity. <br />-The monitoring plan for the 87 tank includes notes regarding the 89 and 91 tanks. <br />The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br />into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a Class II violation. <br />113 <br />CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br />A monitoring system certification, leak detector testing, and spill container testing were performed on 5/31/17. A test <br />report has not been submitted to the EHD or the California Environmental Reporting System (CERS). A copy of the <br />test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br />This is a Class II violation. <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on May 31, 2017 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by June 30, 2017 . This <br />information has not been received resulting in a non-compliant status for this facility. The outstanding violations <br />include: <br />-UST system is not operated to prevent unauthorized releases. <br />An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a <br />written response documenting corrective actions taken or proposed is submitted within 30 days of receiving an <br />inspection report. <br />This is a repeat violation, Class II. <br />206 <br />CCR 2712 Failure to comply with UST operating permit conditions. <br />A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br />and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br />This is a Class II violation. <br />FA0003772 PR0232469 SC001 05/15/2018 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.