Laserfiche WebLink
MONITOR., ING SYSTEM CERTIFIC TION <br /> F e By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7,H and Safety Code,Chapter 16,Division 3 title 23, is Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating LIST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: FLYING J City: RIPON CA Zip:95366 <br /> Site Address: 1501 N.JACK TONE RD Contact Phone No: 599-4141 <br /> Date of Testing/Service: 04/17/2006 <br /> Facility Contact Person: JOSE <br /> Make/Model of Monitoring System:VEEDER TLS350 Work Order Number: 2242139 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: PREM Tank ID: PLUS <br /> -U1 OEL Gauging Probe. Model: OEL 8000 X In-Tank Gauging Probe. Model: OEL 8000 <br /> X Annular Space or Vault Sensor. Model: 794380-302 Annular Space or Vault Sensor. Model: 794380-302 <br /> X Piping Sump/Trench Sensor(s). Model: 794380-208 Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: FX1 V <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detecto, Model: <br /> Tank OverfillMigh-Level Sensor. Model: Tank OverfilUHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: KtUULAK TanklD: <br /> X In-Tank Gauging Probe. Model: OEL 8000 In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 794380-302 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 794380-208 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> )( Electronic Line Leak Detector. Model: MLD Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Others <br /> ( pacify equipment type and model in Section E on page 2). <br /> Dispenser : 1-2 Dispenser ID: 3-4 <br /> X�Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s) Model:794380-208 <br /> FXJ Shear Valve(s). —X-1 Shear Valves) <br /> F]Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> Xi Dispenser Containment Sensor(s) Model:794380-208 71 Dispenser Containment Sensor(s). Model:794380-208 <br /> 11 <br /> Shear valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> 0 Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s). Model:794380-208 <br /> Q Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ANEIL CHAND Signature: <br /> Certification No.: 006-05-1935 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 04/17/2006 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />