Laserfiche WebLink
SWRCB,January 2002 0 Is Page A Z of <br /> 18. UNDER-DISPENSER CONTAINAMNT(UDQ TESTING <br /> Test Method Developed By: 0 UDC Manufacturer 0 Industry Standard X Professional Engineer <br /> El Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> oTestEquipment Used: MTS Mag Probe W/TDU Meter Equipment Resolution: .001" <br /> UDC#13-Satellite UDC#9/10 UDC#11/12 UDC# <br /> w e <br /> s Co <br /> Fiber <br /> r <br /> 26" <br /> 'jl)c7 <br /> UDC Manufacturer: Owens Corrin Owens Corniag Owens Corrin <br /> UDC Material: Fiber ass Fiberglass Fiberglass <br /> UDC Depth: 276" 26" 26" <br /> Height from UDC Bottom-to Top 1294 13'7 1294 <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 6" 6" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good <br /> testing: <br /> Portion of UDC Tested14" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 0 Yes X No 0 NA 0 Yes XNoDNA 0 Yes X No 0 NA 0 Yes 0 No 0 NA <br /> product and w ?* <br /> Turbine shutdown res time N/A N/A N/A <br /> Is system programmed for fail- 0 Yes X No 0 NA 0 Yes XNoONA 0 Yes X No 11 NA 0 Yes 0 No 0 NA <br /> safe shutdown?* <br /> Was fail-safe verified to be <br /> oratiol?* 0 Yes XNo D NA 0 Yes XNoONA 0 Yes X DNA 0 Yes 0 No 0 NA <br /> pena <br /> Wait a between applying__ <br /> pressure/vacuum/water and 10 in 10 Min 10 in <br /> q�,�Im test <br /> Test Start Time: 16:33 17:00 17:00 <br /> Initial Reading(Rj):_ 0.0w, 0.0 9' 0.0001, 0,00011 <br /> Test End Time: 16:45 17:12 17:12 <br /> Final Reading(RF): 0.0(W, 0. '4 0.000V9 <br /> Test Duration: 12 in 12 in 12 in 12 in <br /> Change in Reading(RF-R,): 0.0001, 0.0 001, 0.0001, <br /> Pass/Fail Threshold or Criteria: +/-.002" +/-.00211 +/- .002" +/- .002" <br /> Tot <br /> x P*w gF81I a fon x hin Rauk. 13 frial 0 Em 0 Fall <br /> Was sensor removed for testing? X Yes 0 No 0 NA X Yes 0 No 0 NA X Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was sensor property replaced and X Yes 0 No DNA X Yes ONo DNA X Yes El No 0 NA 0 Yes 0 No o NA <br /> verified functional after testing? . <br /> Comments—(include information on repairs made ELjor to testin&, and recommende!t�Iow-MEZfo2r�failed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to gny of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SB LG-160) <br />