Laserfiche WebLink
SWRCB,January 2002 Page 1"1 of <br /> 23. UNDER-DISPENSER CONTAINME EMC <br /> —)TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard X Professional Engineer <br /> ®Other(Spec) <br /> Test Method Used: ❑Pressure 0 Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: MTS Mag Probe W/TDU Meter Equipment Resolution: .001" <br /> U # <br /> 25-Satellite UDC#26 UDC#26-Satellite UDC#27 <br /> U Manufacturer: Owens Co 'n Owens Co 'n Owens Corrin Owens Kornis <br /> UDC Material: Fiber lass Fi!!SrAass Fiberglass Fiber ! s <br /> UDC Depth: 26" 26" 26" 26' <br /> Height <br /> from Bottom <br /> to Top 999 �p 99 915 (199 <br /> of Hi est Piping Penetration: S 9 3 <br /> Height from UDC Bottom to 5" 5" 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to (I d Good Good Good <br /> testis <br /> Portion of UDC Tested 1.2" 12" 12" 12" <br /> Does turbine shut down when <br /> UDC sensor detects liquid ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No ❑NA <br /> rouct and water)?" <br /> Turbine shutdown re time /A N/A N/A /A <br /> Is system programmed for fail- ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes XNo ❑NA ❑Yes X No ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No ❑ A <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 10 Min 10 Min 10 Min 10 Min <br /> starting test <br /> Test Start Time: 15:15 15:15 15:35 15:35 <br /> Initial Reading(RO: 0. 0. 0" 0.000" 0. 0" <br /> Test End Time: 15:27 15:27 15:47 15:47 <br /> Final Reading(RF): 0.0w, 0.0001, -0.001 0.000" <br /> Test tion: 1.2 in 12 in 12 in 12 in <br /> C e in ea Rs). 0. 0.000" -0.0011, 0.00094 <br /> Pas ail Thresholdor Criteria: +/-,002 +/-.002" +/-.002" +/-.002" <br /> 1 i ❑ U van <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments--(include information on repairs made prior to testing, and recommended oqT us or ailed tests) <br /> i If the entire depth of the UDC is not tested,specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />