SWRCB,January 2002 0 0 Page 1I of c13 <br /> 24. UNDER-DISPENSER CONTAINMENT(UDQ TESTING <br /> Test Method Developed By: 0 UDC Manufacturer 0 Industry Standard X Professional Engineer <br /> 11 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: MTS Mag Probe W/TDU Meter Equipment Resolution: .001" <br /> UDC EMENSEEM MINE= MEMENESEM <br /> :27-Sateflite UDC#28 UDC#28-Satelfite I UDC#29 <br /> UDC Manufacturer: Owens Corning Owens Coming Owens S221jM_ Owens Cornin <br /> UDC Material: FibEg!;!�� Fiberglass FibeMlass Fiberglass <br /> UDC RTth: 26" 26" 26)' 2615 <br /> Height from UDC Bottom to Top 91, V 91, 97, <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5" 5" 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good Good <br /> testing: <br /> Portion of UDC Tested1211 12" 12" 12" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 0 Yes XNo DNA 0 Yes XNo DNA DYes XNo DNA 11 Yes XNo DNA <br /> pLuct and water)?* <br /> Turbine shutdown reTonse time N/A N/A N/A N/A <br /> Is system programmed for fail- 0 Yes XNo DNA 0 Yes X DNA DYes XNo DNA 0 Yes XNo DNA <br /> safe shutdown?* <br /> Waserationalf fail-safe verified to be <br /> 2p 0 Yes X No 0 NA 0 Yes X No DNA D Yes X No DNA 0 Yes XNo DNA <br /> Wait time between applying <br /> pressure/vacuum/water and 10 in 10 in 10 in 10 in <br /> starting test <br /> Test Start Time: 16:13 16:13 16:40 16:40 <br /> Initial Reading(Rj): 0.0001, 0.0m" 0.(M" 0.0001, <br /> Test End Time: 16:25 16:25 16:52 16:52 <br /> Final Readi!jg(RF): 0.0w, 0.0 001, 0. 0" 0.0w, <br /> Test Duration: 12 in 12 in 12 in 12 Min <br /> Change in Reading(RF-Rj): 0.(M" 0.0001, <br /> Pass/Fail Threshold or Criteria: +/-.002" .002" +/-.002" +/-.002" <br /> X Pass 9 Fall <br /> P" a Fill x I'm a Pau X Pass 0 Faft <br /> tas�sensor removed for testing? XYes DNo DNA X Yes 0 No 0 NA X Yes 0 No 0 NA XYes ONo DNA , <br /> Was sensor properlyreplaced and <br /> verified functional after testing? X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No 0 NA <br /> Comments—(inelude in�ati�onon re airs made prior to testing, and recommended follow-upforfailed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SB LG-160) <br />