Laserfiche WebLink
600 <br />AW C1114 to <br />UNIFIED PROGRAM CONSOLIDATED FORM 1 �31 /D <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanert closure or removal, completeonly this section and Sections 1, II, III, IV, and IX below) 430 <br />❑ 1. NEW PERMIT ® 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 4306 <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />- <br />I <br />® <br />_ <br />l' / <br />6 <br />-7 <br />Z <br />1 <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3 <br />Flying J Travel Plaza - #618 <br />BUSINESS SITE ADDRESS 107 <br />CITY 104 <br />1501 N. Jack Tone Rd 1 <br />Ripon <br />H. TANK DESCRIPTION <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />TANK CONFIGURATION: THIS TANK IS 434 <br />® LA STAND-ALONE TANK <br />1 <br />O� <br />❑ 2. ONE IN A COMPARTMENTED UNIT. <br />Complete one page for each compartment in the unit. <br />DATE UST SYSTEM INSTALLED 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT 437 <br />20000 <br />1 <br />III. TANK USE AND CONTENTS <br />TANK USE ID la. MOTOR VEHICLE FUELING ❑ 1b. MARINA FUELING ❑ Ic. AVIATION FUELING 439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE Oncludes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL (HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99, OTHER (Specify): 439a <br />CONTENTS PETROLEUM: ❑ la. REGULAR UNLEADED ❑ lc. MIDGRADEUNLEADED ❑ lb. PREMIUM UNLEADED 440 <br />N 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ METHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): 440h <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ® 2. DOUBLE WALL ❑ 95. UNKNOWN 443 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ® 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 444 <br />❑ 7. STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 444a <br />SECONDARY CONTAINMENT ❑ I. STEEL ® 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED 445 <br />❑ 90. NONE ❑ 95. UNKNOWN [199. OTHER (Specify): 445a <br />OVERFILL PREVENTION ® 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT ® 3. FILL TUBE SHUT-OFF VALVE 452 <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT/ WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ❑ 1. SINGLE -WALLED ® 2. DOUBLE -WALLED ❑ 99. OTHER 460 <br />SYSTEM TYPE ® L PRESSURE ❑ 2. GRAVITY ❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] 458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): 464a <br />SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGIDPLASTIC 4646 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 464c <br />PIPING/TMTNE CONTAINMENT SUMP TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 464d <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ❑ L STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464c <br />464el <br />VENT SECONDARY CONTAINMENT ❑ ].STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464f <br />4641`1 <br />VR PRIMARY CONTAINMENT ❑ L STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4648 <br />464 I <br />VR SECONDARY CONTAINMENT 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464h <br />464h1 <br />VENT PIPING TRANSITION SUMP TYPE ❑ I. SINGLE WALL ❑ 2. DOUBLE WALL ® 90. NONE 4641. <br />RISER PRIMARY CONTAINMENT 0 L STEEL Lj 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464] <br />464' I <br />RISER SECONDARY CONTAINMENT ❑ L STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90, NONE ❑ 99. OTHER (Specify) 464k <br />464k1 <br />FILL COMPONENTS INSTALLED ® 1. SPILL BUCKET ® 3. STRIKER PLATEIBOTTOM PROTECTOR ® 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ® I. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE 469a <br />CONSTRUCTION MATERIAL ❑ L STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 4696-c <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ® 6. ISOLATION 448. <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full om liancewith legal requirements. <br />A PP <br />DATE 9 4770 <br />-�-ia <br />AP CA NAME(ptInt) 471' <br />APPLICANT TITLE 472. <br />Joey Cupp <br />Environment Management <br />UPCF UST -B - 2/23 Rev. (12/2007) <br />