Laserfiche WebLink
v <br />UNIFIED PROGRAM CONSOLIDATED FORM aI /�3/� <br />UNDERGROUND STORAGE TANK t <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (one form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanert closure or removal, completeonly this section and Sections 1,11,111, 1V, and 1X below) 430 <br />❑ L NEW PERMIT ® 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430a I DATE EXISTING UST DISCOVERED: 430b <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />r r+ <br />JAI <br />_ <br />lololol-ld <br />! l' <br />-7 <br />-L <br />1 <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3 <br />Flying J Travel Plaza - #618 <br />BUSINESS SITE ADDRESS 103 <br />CITY 104 <br />1501 N. Jack Tone Rd <br />Ripon <br />II. TANK DESCRIPTION <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />TANK CONFIGURATION: THIS TANK IS 434 <br />®1, A STAND-ALONE TANK <br />3 7-A 05-05 7,0 <br />0 <br />❑ 2. ONE IN A COMPARTMENTED UNIT. <br />Complete one page for each compartment in the unit. <br />DATE UST SYSTEM INSTALLED 435 <br />TANK CAPACITY M GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT 437 <br />20000 <br />1 <br />III. TANK USE AND CONTENTS <br />TANK USE ® la. MOTOR VEHICLE FUELING ❑ Ib. MARINA FUELING ❑ to. AVIATION FUELING 439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil ❑ 5. EMERGENCY GENERATOR FUEL [HSC §2S281.5(c)) <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99.OTHER (Specify): 439a <br />CONTENTS PETROLEUM: ❑ 1 a. REGULAR UNLEADED ❑ Ic. MIDGRADE UNLEADED ❑ Ib. PREMIUM UNLEADED 440 <br />® 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): 440b <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ® 2. DOUBLE WALL ❑ 95. UNKNOWN 443 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ® 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 444 <br />❑ 7. STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 444a <br />SECONDARY CONTAINMENT ❑ I. STEEL ® 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED 445 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (S eci 445. <br />OVERFILL PREVENTION ® I. AUDIBLE & VISUAL ALARMS Ll2. BALL FLOAT ® 3. FILL TUBE SHUT-OFF VALVE 452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT J WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ❑ 1. SINGLE -WALLED ® 2. DOUBLE -WALLED [199. OTHER 460 <br />SYSTEM TYPE ® 1. PRESSURE ❑ 2. GRAVITY ❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)) 458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): 464a <br />SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 4646 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 464c <br />PTPTN TURBINE CONTAINMENT SUMP TYPE N 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 464d <br />VI. VENT, VAPOR RECOVERY {VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464e <br />464e1 <br />VENT SECONDARY CONTAINMENT 1. STEEL 10 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464f <br />464fl <br />VR PRIMARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464g <br />464g) <br />VR SECONDARY CONTAINMENT ❑ 1. STEEL 10 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464h <br />464h1 <br />VENT PIPING TRANSITION SUMP TYPE ❑ I. SINGLE WALL ❑ 2. DOUBLE WALL 10 90. NONE 4641. <br />RISER PRIMARY CONTAINMENT ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464j <br />464'1 <br />RISER SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464k <br />464k1 <br />FILL COMPONENTS INSTALLED ® 1. SPILL BUCKET ® 3. STRIKER PLATE/BOTTOM PROTECTOR ® 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE 469a <br />CONSTRUCTION MATERIAL ❑ I. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 469b•c <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ® 6. ISOLATION 448. <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full compliance with legal requirements. <br />AP NAT <br />DATE 470. <br />(pnt) 471' <br />PLICANT N a <br />APPLICANT TITLE 472. <br />Joey Cupp <br />Environment Management <br />IUPCF UST -B - 1/23 Rev. (12/2007) <br />