My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® Fg-)I �fP1, ,[gin <br />FIED PROGRAM CONSOLIDATED FO <br />UNDERGROUND STORAGE TANK l y I <br />MONITORING PLAN - (Pae 1 of 2 <br />TYPE OF ACTION ❑ 1. NEW PLAN ® 2. CHANGE OF INFORMATION : N ,. 9 a <br />490-1. <br />PLAN TYPE ❑ 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. PER t - 0-o E <br />490-2. <br />(Check one item only) ® 2. THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): DIESEL TANK #1,2,3 8c 6. GASOLINE <br />TANKS #48x5. <br />77�T(� T �7 . <br />' as'�.;a RMA�l®l�,a <br />'"%;'. <br /><, ;" .r x,•,:: i., �,s,', a,e���T 1'® <br />FACILITY ID # (Agency Use Only) <br />BUSINESS NAME (Same as Facility Name or DBA) FLYING J TRAVEL PLAZA <br />3. <br />BUSINESS SITE ADDRESS 1501 NORTH JACK TONE ROAD 103. <br />CrIY RIPON <br />104• <br />LL+. M .. `uu G PREVENTIVE MAIl 'ENt�CEy�� �. <br />Testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) must be performed at the frequency specified <br />the equipment manufacturers' instructions, or annually, whichever is more frequent. Such work must be performed by qualifie, d personnel. [23 CCR §2632; 2634, 3826411 <br />MONITORING EQUIPMENT IS SERVICED ® 1. ANNUALLY ❑ 99. OTHER (Specify): <br />490-3b. <br />Rm <br />T%MOivITOF1ING;Ie®ATIONS <br />r[23 <br />❑ 1. NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2. SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED CCR §2632,26341 <br />490-4. <br />az <br />® 1. CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) <br />490-5. <br />WITH AUDIBLE AND VISUAL ALARMS. [23 CCR §2632,26341 <br />SECONDARY CONTAINMENT IS: ® a. DRY Z b. LIQUID FILLED ❑ c. PRESSURIZED ❑ d. UNDER VACUUM <br />490-6. <br />PANEL MANUFACTURER: VEEDER-ROOT 490-7. MODEL#: TLS -350 <br />490-8. <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-9. MODEL AS): 303 <br />490-10. <br />.._......... ...._._..._......_... ....... ..�........._ _ _.. _._. ....... <br />2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S). [23 CCR §26431 <br />a9au <br />PANEL MANUFACTURER: 490-12. MODEL #: <br />490-13. <br />IN -TANK PROBE MANUFACTURER: 490-14. MODEL #(S): <br />490-15. <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILY/NIGHTLY ❑ c. WEEKLY <br />490-16. <br />❑ d. MONTHLY ❑ e. OTHER (Specify): 490-17. <br />PROGRAMMED TESTS: ❑ a. 0.1 h. ❑ b. 0.2 h. ❑ c. OTHER (Specify): 490-I8. <br />_. _...._......._.._......_. _.v __. ___.__ _..__...................................................................._................... a90-19. <br />.... g.p.h. g:p:............._..................._.......�_.._._.__.. 1? <br />.._�._.. <br />❑ 3. MONTHLY STATISTICAL INVENTORY RECONCILIATION [23 CCR §2646.11 <br />.L� ......... <br />490-20. <br />.................0 21 "" <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) [23 CCR §26451••••••••_•••••••••••• _........."""""""""TESTING PERIOD: " ❑ a. 36 HOURS .❑."""b. 60 HOURS - <br />....._....._...._......._........._................_....._.............._...._...� 490-22 <br />_.._....._............_.._.._._.................................................................................._......................_.__.�__...___....._....._.........__...._.........._..a....._.._....__._........_.................................b...._...._._.............-.--.-..._..._..._._._............... <br />-22...._........ <br />❑ 5. TANK INTEGRITY TESTING PER [23 CCR 02643.11 <br />490-23. <br />TEST FREQUENCY: Ela. ANNUALLY ❑ b. BIENNIALLY [3 o T 490-24. <br />pecOTHER (Specify): 490-25; <br />® 99. OTHER (specify): VISUAL DONE DAILY <br />•_•..•. <br />49426. <br />W, p;w1WW <br />p�,,�,.490-27. <br />V: PH'E M(�8Q US G THE SOL <br />� <br />® 1. CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE & VISUAL ALARMS. <br />490-28. <br />[23 CCR <br />§26361 SECONDARY CONTAINMENT IS: ® a. DRY Elb. LIQUID FILLED ❑ c. PRESSURIZED [Id. UNDER VACUUM <br />361 <br />490-29. <br />PANEL MANUFACTURER: VEEDER-ROOT 490-30. MODEL#: TLS -350 <br />490-31. <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-32. MODEL #(S): 208 <br />490-33. <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. ® a. YES ❑ b. NO <br />490-34. <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a. YES b. NO <br />490-35. <br />_❑ <br />® 2. MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br />496=367 <br />PRODUCT FLAW WHEN A LEAK IS DETECTED. [23 CCR§26361 <br />MLLDMANUFACTURER(S): RED JACKET/VAPORLESS 490-37. MODEL#(S): RJ 116-059-5/LD2000 <br />_....._..._.......... .............. _.. _._......_...... <br />490-38. <br />_...._......_.................... <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS. [23 ccR§2636] <br />490-39. <br />ELLD MANUFACTURER(S): 490-40. MODEL #(S): <br />490-41. <br />PROGRAMMED IN LINE LEAK TEST: ❑ a. MINIMUM MONTHLY 0.2 g.p.h. ❑ b. MINIMUM ANNUAL 0.1 g.p.h. <br />490-42. <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />490-43. <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />_. _...._.._.........._.._._.............. .................. _. _.__...__...__...._._. <br />490-44. <br />❑ 4. PIPE INTEGRITY TESTING. <br />490-45. <br />90-46. <br />TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS ® c. OTHER (Specify) N/A D/T os.shutdown 447. <br />_....._....._............................................. ..._Q.._._..._....._.._.....__-.._._....................................................._. ._.. ...................._�._..... ....��.... ....49447......_. <br />® 5. VISUAL PIPE MONITORING. <br />490-48. <br />FREQUENCY: ® a. DAILY ❑ b. WEEKLY ❑ C. MIN. MONTHLY & EACH TIME SYSTEM OPERATED* <br />490-49. <br />.x Allowed for monitoring of unburied emergency generator fuelpiping.only per.HSC §25281. S(W <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA. [23 CCR §2636(a)(3)1 <br />490-50. <br />❑ 7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. <br />49451. <br />_....._.__._...._....__......_......................__..._.......... ....... ............ <br />❑ 99. OTHER (Specify) <br />490-52. <br />490-53. <br />UPCF UST -D (12/2007) - 1/6 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.