My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t i< ROGRA-N! CONS01JUATED R <br />�. .1,E) <br />UNDERGROUND STORAGE TANK <br />MONITORING PIAN - (Page 1 ®I2) <br />TYPE OF ACTION El L NEW PLAN ® 2. CHANGE OF INFORMATION 490 <br />PLAN TYPE ❑ 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 400_1 <br />DIESEL TANKS 1,2,3 & 6. GASOLINE <br />(Check one item only) ®2- THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): TANKS #4 & 5 <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />� <br />T <br />I __LLi <br />1. <br />BUSINESS NAME. (Same as Pacilin, Name or DBA) FLYING J TRAVEL PLAZA 3 <br />BUSINESS SITE ADDRESS ,1501 NORTH JACK TONE ROAD "' I CITY RIPON G4. <br />II® EQUIPMENT TESTING AND PREVENTPREVENTWE MAINTENANCE <br />Testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) must be performed at the frequency specified <br />by the equipment manufacturers' instructions, or annually, whichever is more frequent Such work must be performed by qualified personnel. [23 CCR §2632 2634.2638, 26411 <br />.. ...... <br />.......... ...... ......... <br />MONITORING EQUIPMENT IS SERVICED ® 1. ANNUALLY El( P 99. OTHER S ecif�): 490-3490-3b. <br />b. <br />III. MONITORING LOCATIONS <br />-- <br />L--._ <br />❑ 1. NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2. SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR §2632.26341 490-4. <br />'llecal <br />IV. T MONITORING IS PERFORMED USING T FOLLOWING TROD(S) thatak ,ppryJ <br />® 1. CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br />WITH AUDIBLE AND VISUAL ALARMS. [23 CCR §2632.26341 <br />SECONDARY CONTAINMENT IS: Z a. DRY ❑ b. LIQUID FILLED ❑ c. PRESSURIZED ❑ d. UNDER VACUUM 490-6. <br />PANEL MANUFACTURER: VEEDER-ROOT/OMNTEC 490-7. MODEL.#: TLS -350/800011 490-8, <br />490-9. MODEL #(S): 303 490-10 . <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT. <br />......................._._..................................... <br />......................................._............................................................................................................... <br />....... <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S). [23 CCR §26431 490-11. <br />PANEL MANUFACTURER: 490-12. MODEL #: 490-13. <br />IN -TANK PROBE MANUFACTURER: 490-14. MODEL #(S): 490-15. <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILYINIGHTLY ❑ c. WEEKLY 490-16. <br />❑ 490-17. d. MONTHLY ❑ e. OTHER (Specify): <br />q90 -t0-. <br />PROGRAMMED TESTS: ❑ a. 0.1.._g.p_hb. 0.2 g.p.h:..............................._❑..._c. OTHER (Specify).:..._. ......_....... _. ...... 49490:....8...... <br />.............................._❑ <br />.. .......... .................................... ....... _... ............. ._......... _. .. _..... ........ <br />❑ 3. MONTHLY STATISTICAL INVENTORY RECONCILIATION [23 CCR §2646.11 490 2° <br />......................... ..................................._...................... .............. ..... 90 <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) [2 CCR §26451 TESTING PERIOD: ❑ a. 36 HOURS ❑ b. 60 HOURS 4 21 <br />.. .. . ..... .. .. ..... .......... .. .... ..... _ .............. ... ........ .... .. ......,.......... ... .......... .... .......... ........._...... _... ._.......... _...................... .... __.. .... .... .._..... ..... 490-23. <br />❑ 5. TANK INTEGRITY TESTING PER [23 CCR §2643.11 <br />TEST FREQUENCY: <br />.... ............... ........ <br />. ......................................... <br />Z---R9_OTHER(Speci£y)_.VISUAL-DONE-DA6LY _ -0-909026_. <br />V. PIPE MONITORING IS PERFORMED USING T FOLLOWING TROI3(S) (Check <br />that apply) <br />® 1. CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE & VISUAL ALARMS. 411-28. <br />[23 CCR SECONDARY CONTAINMENT IS: Z a. DRY ❑ b. LIQUID FILLED ❑ c. PRESSURIZED ❑ d. UNDER VACUUM 490-29. <br />§2636] <br />PANEL MANUFACTURER: VEEDER-ROOT 490-30. MODEL#: TLS -350 490-31. <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-32 MODEL #(S): 208 490-33. <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. ® a. YES ❑ b. NO 490-34.. <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. Z a. YES ❑ b. NO 490-35. <br />-....-._....__......_._......_..... <br />_..__.._.._._................_..._._...........__....._._..................._......... .......... ... .............................. ................... ................ ............... ............._........ _......... _....... .._._....._..-- <br />® 2. MECHANICAL LINE LEAK DETECTOR (MELD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br />PRODUCT FLOW WHEN A LEAK IS DETECTED. [23 CCR§26361 <br />MLLDMANUFACTURER(S): RED JACKET 49G-37. MODEL#(S): FX1DV, VMI, FE PETRO 490-38. <br />._......9....._........ <br />........................................._....................._..........-............_................_................................I....._..............._._............._..........................._....._ <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS. [23 CCR§2636] 4 0-39. <br />ELLD MANUFACTURER(S): 490-40. MODEL #(S): 490-41. <br />PROGRAMMED IN LINE LEAK TEST: ❑ a. MINIMUM MONTHLY 0.2 g.p.h. ❑ b. MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO 490-43, <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES El b. NO 490-44. <br />............ .................... ............... ........... ........ _........._ . ............. _............... . <br />❑ 4. PIPE INTEGRITY TESTING. 490-45. <br />490-46, <br />TEST FREQUENCY: ❑ a. ANNUALLY El b. EVERY 3 YEARS ® c. OTHER (Specify) N/A D/T os.shutdown 490.47_ <br />................................................................ _........._.._-....... --_. .... .............. ..................... .......... .... . <br />490-0-8. <br />Z 5. VISUAL PIPE MONITORING. <br />FREQUENCY: ® a. DAILY ❑ b. WEEKLY ❑ c MIN. MONTHLY & EACH TIME SYSTEM OPERATED* 490-49. <br />' Allowed for monitonng of,unbuned emergency ¢enerator fuel piping, onl�.per,HSC §2528]5(6)(3) <br />_.... . ... ....._.... ... .._ .... <br />.....__. ... ....... __....... ....... _................................ _. ....._............................................ ... .._... _. ... ..... .......... .. _. .. .. <br />4 <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA. [23 CCR §2636(a)(3)] 90 -so. <br />........................................................................ .................. <br />_....._........._._...................... .... _....._... _............._................_..._......._.......... _... ....-1-................ ............... ........................... .............. _............. ................... ..... ..................... .............................................. ......._................................ .................._..... ......................... .............. ..................................... <br />❑ 7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br />........... ............... .... <br />_ ..................... _.._............_._.........._..........._....................-................... ..........._.........................._....._..._._....................... _.................. ....._.._............................. .............. ..._.............. ...._........_.._........__...................... ............ ........._..-....................................__........................................ ........._......__.... ......_._................._................. ........._... <br />El 99, OTHER (Specify) 490-52. <br />49053. <br />UPCF UST -D (12/2007) - 1/4 www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.