My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WIFIED PROGRAM CONSOLIDATED MW <br />UNDERGROUND STORAGE TANK JI A 2 6 2009 <br />MONITORING PLAN - (Page 1 of 2) <br />IN 1. CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) <br />490-5. <br />WITH AUDIBLE AND VISUAL ALARMS. [23 CCR §2632,2634] <br />SECONDARY CONTAINMENT IS: Z a. DRY El b. LIQUID FILLED [I c. PRESSURIZED El d. UNDER VACUUM <br />490 -6 - <br />PANEL MANUFACTURER: VEEDER-ROOT/OMNTEC 490-7. MODEL #: TLS -350/800011 <br />490-8. <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-9. MODEL #(s ): 303 <br />490-10. <br />❑ 2. AUTOMATIC TANK GAUGING ATG SYSTEM ... ..... .... ..... . ... ... .... <br />USED TO MONITOR SINGLE WALL T A N K ( S 2 3 CCR § 26 431 <br />PANEL MANUFACTURER: 490-12. MODEL #: <br />490-13. <br />IN -TANK PROBE MANUFACTURER: 490-14. MODEL #(S): <br />490-15. <br />LEAK TEST FREQUENCY: [] a. CONTINUOUS ❑ b. DAILY/NIGHTLY El c. WEEKLY <br />490-16. <br />F-1 d. MONTHLY E] e. OTHER (Specify): 490-17. <br />PROGRAMMED TESTS: El a. 0.1 g.p.h. ❑ b. 0.2 g.p.h. 0 c. OTHER (Specify): 490-18. <br />.... ........ ...... . ... . . . .................... . ..... . . . ........................ . .. . ........... ............................. "I'll.,❑ ........................................................... I ..................................... I .... . ............. . . ..... . .................. <br />I ............................................ .............................. - .................... ......... <br />❑ 3. MONTHLY STATISTICAL INVENTORY RECONCILIATION [23 CCR §2646.1] <br />490-20. <br />... .......... .. . . .. -.1- ............................... '. .......................................................... I ............. I ........................... . .............. . ... . .............. . ............... .. . ................ . ................... - ............................ .... ... ........... I...... .................................... I ........... ...................................... .................................. 1- ................ .. . . ............................. . _ I <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) [23 CCR §2645] TESTING PERIOD: n a. 36 HOURS El b. 60 HOURS 490-21. <br />I 490-22. <br />... ........ ................ ...................................................................................❑ ................................. . ........................ - ..... .... . . .... . . . ..................... .... . ................ .... ..' ........... . .............. .............................................................. ................... <br />5. TANK INTEGRITY TESTING PER [23 CCR §2643.1] <br />490-23. <br />ecify): <br />TEST FREQUENCY: 0 a. ANNUALLY [I b. BIENNIALLY El c. OTHER (Sp--- <br />490-24. <br />............ ........................ ........................... .......................... . .. . . . ...... ............... ........ .❑............. . ......................... . ....... . ... . . . .............. . .... .❑ ................................................................................................... .. . . . .. . .................... . .... ... . .......... 490-25. <br />................................ <br />99. OTHER (Specify): VISUAL DONE DAILY <br />.... <br />490-26. <br />490-27. <br />;PIPE m '(Chwk <br />GIS all <br />GMETHO.D(S), <br />4hlitamly)l <br />1. CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE & VISUAL ALARMS. <br />490-21- <br />[23 CCR <br />§26361 SECONDARY CONTAINMENT IS: 0 a. DRY ❑El b. LIQUID FILLED ❑El c. PRESSURIZED El d. UNDER VACUUM <br />490-21. <br />PANEL MANUFACTURER:VEEDER-ROOT 490-30. MODEL #: TLS -350 <br />490-31. <br />LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-32. MODEL#(s): 208 <br />490-33. <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. 0 a. YES ❑ b. No <br />490-34. <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. Z a. YES ❑ b. No <br />.. ................ ..................... <br />490-35. <br />. . . ................................................................................. . . .- ... . ............................................... . ......... . ..... . ... . 2... . . .... .. <br />...................... . ........................... ............ - ............................................................................... . <br />MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br />490-36. <br />PRODUCT FLOW WHEN A LEAK IS DETECTED. [23 CCR§2636] <br />MLLD MANUFACTURER(S):REDJACKET 490-37. MODEL#(s): FXlDV, Vml, FE PETRO <br />.. ........ ................................... . .............................. .... <br />491-38- <br />............................................. . ...... ....... ...... . .. ........ - <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS. [23 CCR§2636] <br />49644. <br />ELLD MANUFACTURER(S): 490-40. MODEL #(S): <br />490-41. <br />PROGRAMMED IN LINE LEAK TEST: El a. MINIMUM MONTHLY 0.2 g.p.h. [I b. MINIMUM ANNUAL 0.1 g.p.h. <br />490-42. <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. [:1 a. YES 0 b. No <br />491-43. <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. El a. YES E] b. No <br />.. .......... ......... . . . . ......................... . .... . ... ......... - ................ . .... -, ..................... ................ <br />490-44- <br />I .......................................... I ....................... . . ......... . ........ . .... . ... . ... . ...................................................................... I .............................. ............................. ............................................................................... . .. I ........................ . ... . ....................... <br />❑ 4. PIPE INTEGRITY TESTING. <br />- <br />490-45. <br />TEST FREQUENCY: El a. ANNUALLY [:1b. EVERY 3 YEARS c. OTHER (Specify) N/A D/Tpos.shutdown 490-46. <br />.. ....................................... . .............. I ...................... .... ... .... . ...................... - ... ... ...... ........................................................ . . . ...... . ................................... ............. <br />I .............................................. .. ........................................................................ <br />... ............. A?2:17 <br />5. VISUAL PIPE MONITORING. <br />.......... <br />490-48. <br />FREQUENCY: a. DAILY [I b. WEEKLY 0 C. MIN. MONTHLY & EACH TIME SYSTEM OPERATED* <br />49049. <br />................................. I ......................................... . . .. . ...... "I . ............ . ................ ......................... - ............................ . ................................................ I .......................... ARned for <br />...................... <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA. [23 CCR §2636(a)(3)] <br />. <br />490-50. <br />.. ........ .............. . . .......................................... - . ............................... . ............. I ........................................................................................................................................................................................... I ....... . ............................................... ................................. 11 ................................... ............................ ................................................ <br />❑ 7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. <br />. ...... <br />490-51. <br />.......... .......................... . ....... . . .. . . ............................................................................................... ................ .... ............. ........................ . .................................. . . . . .. . ........................... . .... . I ....................................................... ... ...... .... .. ... 1. .................................................................... .1, .......................... ......................... .................... . .. I <br />❑ 99. OTHER (Specify) <br />490-52. <br />490-53. <br />UPCF UST -D (12/2007) -1/4 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.