My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />7_ UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Page 5 of 7 <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />t Equipment Used:Incon TS -STS <br />iUDC #1-2 UDC #34 <br />UDC Manufacturer: <br />Equipment Resolution: +/-0.000 1" <br />UDC #5-6 UDC #7-8 <br />UDC Material: <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC Depth: <br />30" <br />30" <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Pi in Penetration: <br />10" <br />10" <br />10" <br />10" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />4" <br />8" <br />9" <br />9" <br />Condition of UDC prior to <br />testin : <br />Clean <br />Clean <br />Clean <br />Clean <br />Portion of UDC Tested <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />®Yes [:]No DNA <br />®Yes [:]No DNA <br />®Yes ❑No DNA <br />®Yes ❑No RNA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?" <br />®yes [:]No [:INA <br />®Yes ❑No DNA <br />®Yes ❑No DNA <br />®Yes [-]No DNA <br />Was fail-safe verified to be <br />operational?` <br />[-]Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />[:]Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />7:36 7:52 <br />7:36 8:10 <br />7:36 7:52 <br />7:36 7:52 <br />Initial Reading (Rt): <br />4.6068 4.6063 <br />2.0299 2.0727 <br />2.4366 2.4357 <br />5.0377 5.0356 <br />Test End Time: <br />7:51 8:08 <br />7:51 8:25 <br />7:51 8:08 <br />7:51 8:08 <br />Final Reading (RF): <br />4.6068 4.6065 <br />2.0298 2.0724 <br />2.4358 2.4354 <br />5.0359 5.0339 <br />Test Duration: <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />Change in Reading (RF -R,): <br />0.0000 1 0.0002 <br />0.0001 1 0.0003 <br />0.0008 0.0003 <br />0.0018 0.0017 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />®Yes ❑No DNA <br />®Yes ❑No ❑NA <br />®Yes ❑No DNA <br />®Yes ❑No DNA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑No DNA <br />®Yes ❑No ❑NA <br />®Yes ❑No DNA <br />®Yes ❑ EI NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Under dispenser containment #1-2,3-4,5-6 & 7-8 all passed hydrostatic test. <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is ' NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.