Laserfiche WebLink
El <br />SWRCB, January 2002 <br />7. <br />Test Method Developed By: <br />Page 5 of 7 <br />UNDER -DISPENSER CONTAINMENT UDC TESTING <br />❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used:Incon TS -STS <br />UDC Manufacturer: <br />UDC #26 Main <br />UDC #27Main <br />Equipment Resolution: +/-0.000 1" <br />UDC #28Main UDC #29 Main <br />UDC Material: <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC Depth: <br />27" <br />27" <br />27" <br />27" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />8" <br />6" <br />8" <br />711 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />4" <br />4" <br />4" <br />7" <br />Condition of UDC prior to <br />testing: <br />Clean <br />Clean <br />Clean <br />Clean <br />Portion of UDC Tested <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />®Yes ❑No ❑NA <br />GlYes ❑No [:]NA <br />[DYes ❑No ❑NA <br />®Yes [:]No ❑NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />®yes [—]No ❑NA <br />®Yes [:]No ❑NA <br />®Yes [:]No ❑NA <br />®Yes ❑No ❑NA <br />Was fail-safe verified to be <br />operational?* <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />[:]Yeses ❑No ONA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />7:24 7:45 <br />7:05 7:24 <br />7:45 8:02 <br />7:45 8:02 <br />Initial Reading (RI): <br />2.2298 2.2300 <br />3.4961 3.4951 <br />3.9490 3.9479 <br />2.0629 2.0619 <br />Test End Time: <br />7:39 8:00 <br />7:21 7:39 <br />8:00 8:18 <br />8:00 8:18 <br />Final Reading (RF): <br />2.2296 2.2287 <br />3.4958 3.4947 <br />3.9483 3.9474 <br />2.0620 2.0619 <br />Test Duration: <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />Change in Reading (RF -Rt): <br />0.0002 0.0013 <br />0.0003 0.0004 <br />0.0007 0.0005 <br />0.0009 0.0000 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: ' <br />0 Pass ' ® Fail <br />0; Pass ; ❑ Fait <br />Z Pass ❑ Fait <br />® Pass ' ❑ Fait <br />Was sensor removed for testing? <br />®Yes ❑No [:INA <br />®Yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />Was sensor properly replaced and ®Yes ❑No ❑NA ®Yes ❑ <br />verified functional after testing? ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Under dispenser # 26,27,28 and 29 all Passed Hydrostatic test. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />