My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 5 of 7 <br />7. UNDER -DISPENSER CONTAINMENT UDC TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used:Incon TS -STS I Equipment Resolution:+/ -0.0001" <br />UDC #19 <br />UDC Manufacturer: <br />at <br />UDC #20sat <br />UDC #21sat <br />UDC #22 sat <br />UDC Material: <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC Depth: <br />27" <br />27" <br />27" <br />27" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />6" <br />6" <br />T' <br />7" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />4" <br />4" <br />4" <br />5" <br />Condition of UDC prior to <br />testing: <br />Clean <br />Clean <br />Clean <br />Clean <br />Portion of UDC Tested <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />2"above highest Pipe pen <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />®Yes ❑No DNA <br />Dyes ❑No DNA <br />Dyes ❑No DNA <br />Dyes ❑No ❑NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?4 <br />®yes ❑No DNA <br />®Yes ❑No DNA <br />®Yes ❑No ❑NA <br />®Yes ❑No DNA <br />Was fail-safe verified to be <br />operational?* <br />❑yes [:]No ®NA <br />Dyes ❑No ®NA <br />Dyes ❑No ®NA <br />[-]Yes ❑No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />3:10 3:33 <br />3:33 3:50 <br />4:31 4:49 <br />4:31 4:49 <br />Initial Reading (Rt): <br />1.9846 1.9844 <br />4.5303 4.5250 <br />3.0231 3.0237 <br />3.6421 3.6419 <br />Test End Time: <br />3:25 3:48 <br />3:48 4:06 <br />4:46 5:04 <br />4:46 5:04 <br />Final Reading (RF): <br />1.9845 1.9842 <br />4.5290 4.5246 <br />3.0236 3.0237 <br />3.6418 3.6417 <br />Test Duration: <br />15 Min Each (30 Min) <br />15 Min Each (30 Min <br />15 Min Each (30 Min) <br />15 Min Each (30 Min) <br />Change in Reading (RF -Rt): <br />0.0001 0.0002 <br />0.0013 0.0004 <br />0.0005 0.0000 <br />0.0003 0.0002 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />Z Pass ❑ Fait <br />®; Pass ` ❑ Fail <br />0 Pass ❑ Fait <br />® Pass ; ❑ Fail' <br />Was sensor removed for testing? <br />®Yes ❑No DNA <br />®Yes ❑No DNA <br />®Yes ❑No DNA <br />®Yes ❑No DNA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑No DNA <br />®Yes ❑No ❑NA <br />®Yes ❑No DNA <br />®Yes [-]No❑NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Under dispenser # 19,20,21 and 22 sat all passed Hydrostatic test. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is '`NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.