My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Auk <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www.sigov.orq/ehd <br /> is Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618* 1501 N JACK TONE RD RIPON Ma 03 2017 <br /> SUMMARY OF VIOLATIONS;,LL`, <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Liquid was found in the Biodiesel shed transiiton sump on 5/3/17. Secondary containment shall be constructed to <br /> prevent any water intrusion into the system by precipitation, infiltration, or surface runoff. Immediately remove this <br /> liquid, make a hazardous waste determination per Title 22 hazardous waste regulations,and manage accordingly. <br /> Immediately contact a properly licensed,trained, and certified contractor to address the liquid intrusion into the <br /> biodiesel shed transition sump under permit and inspection of the EHD. <br /> This is a Class II violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 grade FE Petro line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A <br /> "UST Retrofit Verification with Inspector Already Onsite"form has been completed and provided to the operator and <br /> contractor. <br /> This was corrected onsite. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection was conducted at this facility on May 3rd,2017, and a checklist was provided on that date. This <br /> complete report replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 6/25/17. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHUS CURRENT HOURLY RATE. <br /> Received by: Date: May 26, 2017 Inspector: Inspector Phone: <br /> ``— Printed Name and Title: AARON HANG, EHS Trainee (209)468-3453 <br /> Scott Brandau,TCGM <br /> Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.