My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Appendix V1MONITORING SYSTEM CERTIFICATION 0- <br /> IUIr',`f 0 2 2017 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6,7, Health and Safety Code;Chapter 16, Division 3, 'Title wwe H,EALT <br /> Regulations I� i'. E <br /> t , <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Pilot Flying J 618 Bld No.: <br /> Facility Name: Y g <br /> Site Address: 1501 N Jacktone Rd City: Ripon Zip: 95366 <br /> Facility Contact Person: Manager Contact Phone No.:( 9 i 599-4141 <br /> Make/Model of Monitoring System: TLS 350 Date of TestingiServicing:0 5 IO 1 J 2 0 1 7 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the aepropriate boxes to indicate specific ufi Ment 1nspected/serviced: -- <br /> TanklD: TanklD: <br /> a In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: _ Annular Space or Vault Sensor. Madel: <br /> Piping Sump/Trench Sensor(s). Model: - Piping Sump I Trench Sensor(s). Model: <br /> FII Sump Sensor(s). Model: Fill Sump Sensor(s), Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model Electronic Line Leak Detector. Model: <br /> Tank Overfill I High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify a ui ment and model in Section E on Page 2). Others ci a ui ment a and model in Section E on Pa e 2). <br /> Tank ID: TankID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump I Trench Sensor(s). Model: - Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill(High-Level Sensor. Model: <br /> Other(specMequipment=and model in Section E on Pae 2). Other s cif ui ment a and model in Section E on Pa <br /> Dispenser ID: 23s Dispenser ID: 24M <br /> Dispenser Containment Sensor(s). Model 794380-208 Dispenser Containment Sensor(s). Model: 794380-208 <br /> Shear Valve(s). - Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). _ Dispenser Containment Float`s and Chains. <br /> Dispenser ID: z4s Dispenser ID: 25M <br /> Dispenser Containment Sensor(s). Model: 794380-208 - Dispenser Containment Sensor(s). Model: 794380-2as <br /> Shear Valve(s). Shear Valve(s). <br /> - Dispenser Containment Float(s)and Chain(s). - Dispenser Containment Floats'and Chain(s). <br /> Dispenser ID: 255 Dispenser ID: 26M <br /> Dispenser Containment Sensor(s). Model: 794380-208 Dispenser Containment Sensor(s). Model: 794380-208 <br /> ShearValve(s). Shear Valve(s). <br /> Disp2nser.Containment Floats and Chain(s - Dispenser Containment Floats and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verity that this Information is correct <br /> and a plot plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): )a System set-up XAlarm tory eport <br /> Technician Name(print): Daniel Marroquin Signature: <br /> Certification No.: 842621 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 ) 972-7581 <br /> Testing Company Address. 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:0 5 IO 112 0 1 7 <br /> Monitoring System Certification page of 12107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.