My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � <br /> AppendIx Y <br /> 0 F: 2011 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions within the state of California m <br /> Authority Cited:chapter 6.7, Health and Safety ode,Chapter 16, Division , . I �. til i <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Infon-nation <br /> Facility Name: Pilot Flying J 618 Bldg.No.: <br /> Site Address: <br /> 1501 N Jacktone Rd City: Ripon ZIP: 95366 <br /> Facility Contact Person: Manager Contact Phone No.:(20_ 9 ) 599-4941 <br /> Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing:0 !a 11 2 0 1 7 <br /> 8. Inventory of Equipment Tested/Certified <br /> Check the agEroDriate boxes to indicates cific ui anent ins eted/serviced: <br /> Tank ID: Tank ID <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump!Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Mechanical <br /> Sump Sen . Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Linnee Leak Detector. Model: <br /> EElectronic Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model Tank Overfill!High-Level Sensor. Model: <br /> Others ci e ui ment a and model in Section E on Pae 2. Others ci a ui ent a and model in Section Eon Pae 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: - In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensoria}. Model: Piping Sump/Trench Sensor(s). Model: <br /> Model: Fill Sump Sensor(s). Model: <br /> Fill Sump p/Trench <br /> Mechanical Line Leak Detector. Model Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other s eci equipment a and model in Section E on Pa e 2. Other s eci ui ment a and model in Section E on Pa e 2. <br /> Dispenser ID- 26s Dispenser ID: 27M <br /> Dispenser Containment Sensor(s). Model: 7M80-208 = Dispenser Containment Sensor(s). Model: 794380-208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dis enser Containment Floats and Chains. Dis enser Containment Floats and Chains. <br /> Dispenser iD: 275 Dispenser ID: 28rn <br /> s Dispenser Containment Sensor(s). Model: 7�so-248 � Dispenser Containment Sensor(s). Model: 794380-toe <br /> Shear Valve(s). = Shear Vaive(s). <br /> Dis enser Containment Floats and Chains. = Dis enser Containment Floats and Chains. <br /> Dispenser ID: 289 Dispenser!D: 2sM <br /> Dispenser Containment Sensor(s). Model: 794390-204 Dispenser Containment Sensor(a). Model: 794380-208 <br /> Shear Vaive(s). Shear s). <br /> Dis enser Containment Floats and Chains r Dis usserer C Containment Floats and Chain(s). <br /> `If the taicContains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report,(check all that aAplY): V System set-up y Alarm h 9 tory report <br /> Technician Name(print): Daniel Marroquin Signature: <br /> Certification No.: <br /> 842821 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group,Inc. Phone No.: 8S( 8 } 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:0 5/0 1 i 2 0 1 7 <br /> Monitoring System Certification Page of 12107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.