COMPLIANCE INFO_2016-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />Page 11 of 14 <br />7. UNDER -DISPENSER CONTAINMENT UDC TESTING <br />Test Method Developed By: <br />❑ UDC Manufacturer J Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />J Hydrostatic <br />Test Equipment Used: INCON TS -STS <br />Equipment Resolution: +/-0.002" <br />UDC Manufacturer: <br />UDC # 23 Master <br />Unknown <br />UDC # 23 Satellite <br />Unknown <br />UDC # 24 Master <br />Unknown <br />UDC # 24 Satellite <br />Unknown <br />UDC Material: <br />Fiber lass <br />Fiberglass <br />Fiber lass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />14" <br />13" <br />14" <br />13" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />91, <br />91, <br />10" <br />9" <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC Tested <br />18" <br />17" <br />18" <br />17" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?' <br />❑ Yes ❑No ® NA <br />❑ Yes ❑ No J NA <br />❑ Yes ❑ No J NA <br />❑ Yes ❑ No <br />J NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?' <br />❑ Yes ❑No X NA <br />71 Yes 11No A NA <br />❑Yes F1No JNA <br />_1 Yes ElNo <br />JNA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No KNA <br />0 Yes ❑ No J NA <br />❑ Yes ❑ No J NA <br />❑ Yes ❑ No <br />J NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15min <br />15min <br />15min <br />15min <br />Test Start Time: <br />11:01 am <br />12:22pm <br />11:53am <br />3:23pm <br />Initial Reading RI): <br />3.4220" <br />2.6587" <br />3.1750" <br />2.4021 " <br />Test End Time: <br />11:16am <br />12:38pm <br />12:08pm <br />3:38pm <br />Final Reading (RF): <br />3.4217" <br />2.6587" <br />3.1754" <br />2.4040" <br />Test Duration: <br />15min <br />15min <br />15min <br />15min <br />Chane in Reading (RF -RI): <br />0.0003" <br />0.0000" <br />0.0004" <br />0.0019" <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />M Pass D Fail <br />® Pass 0 Fail <br />® Pass ` 0 Fail < <br />® Pass 0 Fail <br />Was sensor removed for testing? <br />IN Yes ❑No ❑ NA <br />J Yes ❑ No ❑ NA <br />J Yes ❑ No ❑ NA <br />J Yes ❑ No <br />❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes []No ❑ NA <br />Yes F-1No[INA <br />®Yes F] No 11 NA <br />J Yes L-1No <br />F1 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests <br />ENVIRCMMENTAL�LTH <br />OERARTMENT <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />