SWRCB, January 2002 <br />7. UNDER -DISPENSER CONTAINMENT UDQ TESTING <br />Page 12 <br />of 14 <br />Test Method Developed By: <br />❑ UDC Manufacturer -A Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: INCO N TS -STS <br />Equipment Resolution: +/-0.002" <br />UDC Manufacturer: <br />UDC # 25 Master <br />Unknown <br />UDC # 25 Satellite <br />Unknown <br />UDC # 26 Master <br />Unknown <br />UDC # 26 Satellite <br />Unknown <br />UDC Material: <br />Fiber lass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30" <br />30" <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />14" <br />13" <br />13" <br />13" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />10" <br />9" <br />9" <br />9" <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC Tested <br />17" <br />17" <br />17" <br />17" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />❑ Yes ❑No 9 NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No 9 NA <br />❑ Yes ❑ No <br />® NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?` <br />❑ Yes ❑No ja NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No 9 NA <br />❑ Yes ❑ No <br />'X NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No KNA <br />❑ Yes ❑ No X NA <br />❑ Yes ❑ No JNA <br />❑ Yes ❑ No <br />® NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15min <br />15min <br />15min <br />15min <br />Test Start Time: <br />5:25pm <br />3:35pm <br />3:35pm <br />4:08pm <br />Initial Reading RI : <br />3.3416" <br />3.0203" <br />3.1708" <br />2.8615" <br />Test End Time: <br />5:40pm <br />3:50pm <br />3:50pm <br />4:23pm <br />Final Reading (RF): <br />3.3412" <br />3.0201" <br />3.1704" <br />2.8611" <br />Test Duration: <br />15min <br />15min <br />15min <br />15min <br />Chane in Reading RF -RI): <br />0.0004" <br />0.0002" <br />0.0004" <br />0.0004" <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />® Pass ❑ Fail <br />N Pass `_ ❑ Fail- <br />19 Pass ❑ Fail' <br />® Pass ❑ Fait <br />Was sensor removed for testing? <br />® Yes ❑No ❑ NA <br />K Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />!XJ Yes ❑ No <br />❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />Yes ]No :1 NA <br />Yes El No 11 NA <br />Yes 11 No 11 NA <br />XJ Yes ELINo❑ <br />NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />I ` <br />1__P't RT M - N <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />