PILOT TRAVEL CENTERS <br />LLC <br />FLYING J,,: <br />June 27, 2016 <br />Ms. Elena Manzo <br />San Joaquin County Environmental Health Department <br />1868 East Hazelton Ave. <br />Stockton, CA 95202 <br />Email: emanzo@sjcehd.com <br />Re: Underground Storage Tank Program Inspection Report <br />Flying J Travel Plaza #618 <br />1501 N. Jack Tone Rd. <br />Ripon, CA 95366 <br />Dear Ms. Manzo: <br />JUN 2 9 2016 <br />Sent via Email <br />This letter is related to issues noted on the Underground Storage Tank (UST) Inspection Report, <br />completed by the San Joaquin County Environmental Health Department (EHD) on May 4 and May 6, <br />2016, amended on May 13, 2016, and received on May 25, 2016 via certified mail. Please find below a <br />list of the violations noted at the referenced facility and Pilot's response. <br />1. UST Operating Permit Application for Facility and Tank Information not submitted or current. <br />UST Tank Information forms for all existing USTs are not current in CERS. All tank forms <br />(except the oil water separator) indicated that Audible/Visual alarms are utilized in addition to <br />the Fill Tube Shut-off Valve for overfill protection. The oil water separator tank's form <br />indicated that no spill container is installed and only Audible/Visual alarms are utilized; a spill <br />container and a fill tube shut-off valve only was present on this tank. Also, the onsite <br />technician indicated that no audible/visual alarms utilized for overfill protection could be <br />located. Any change of information must be updated in CERS within 30 days of the changes. <br />Immediately log into CERS, update the required information, and submit for review by the <br />EHD. <br />This is a Class II violation. <br />This information has been changed in CERS and submitted for review. <br />Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plan for <br />the onsite oil water separator indicates that the leak alarm triggers the automatic pump shut <br />down and failure or disconnection of the sensor also triggers an automatic pump shut down. <br />The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). Immediately log into CERS, make the necessary changes, and submit for review by <br />the EHD. <br />The Customer 1Oriven Company <br />Pilot Travel Centers LLC • P.O. Box 10146 • Knoxville, TN 37939-0146 • (865) 588-7488 <br />