Laserfiche WebLink
5/8/2018 <br />10 <br />JONES COVEY CROUP, INC. <br />9595 Lucas Ranch Road Suite 100 <br />Rancho Cucamonga, California 91730 <br />(888)972-7581 <br />info@JonesCovey.com <br />DATE <br />01/04/2018 <br />.................................................. <br />TIME <br />.............................. <br />12:30 pm - 04:15 pm <br />....................... <br />DURATION <br />............................. <br />3h 45m <br />. ............................................._......._. <br />TECH(S) <br />1- .. ..... ....... ............... ........................... <br />J. Blaine <br />_ ............................... .._.._..._................... ........... ................ <br />JOB# <br />9607524 <br />......................... <br />_.........._ <br />PO# <br />.............._...._...._....._.........._--_.... _........ ,...._....... <br />183635-6040902 <br />PAYMENT <br />Direct Bill, NET 45 <br />CUSTOMER SERVICE LOCATION <br />Thank you for allowing Jones Covey Group, Inc. to be your Pilot Flying J 618 Ripon <br />service partner! 1501 N. Jack Tone Road <br />Ripon, CA 95366 <br />JOB DETAILS — JAMES CALL ME- <br />-Pilot shipped/supplied the Controller and turbine. Parts shipped to the site- <br />1/17/2018—ADD-ON/ <br />ite- <br />1/17/201&-ADD-ON/ Tank 2 leaks again at the joint for the fuel drop. They need to take apart and put plenty of pipe <br />dope on it like they did for tank 3. Lead fuel driver complained to me today about it. RECALL- All truck diesel is <br />intermittently going into slow flow. Need tech out to inspect and repair. P0#1 83635-6040902. <br />01/04 Arrived onsite checked in at kiosk. Checked in with manager. Performed troubleshooting on D21 -D30 slow <br />flow. Site says they have been having less slow flows since previous work was done. Checked the handle hooks <br />again, all 2 stage valves again, took pressure readings and isolated T3 turbine to run only off T2. Experienced 2 <br />slow flows while on site. Amps on power leads to T2 turbine are low. STP -SCI II Controller still flashing alarm code <br />13. Unbalanced load in. Checked all breakers on sub panel and all barely within tolerance with low voltage output. <br />This was already looked at by PG&E & site was told everything is normal. T2 turbine still working but not able to <br />quite meet demand. With low voltage coming in it brings to question what is making T2 turbine underperform at <br />times, but according to Franklin Fueling controller is still within tolerances. Changed T2 master to slave, & T3 to <br />master & recalibrated controllers. Turbine still ohms out properly. I would recommend replacement of STP-SCIII <br />Controller & T2 Turbine to resolve issues. Turbine Is old style Red Jacket Big Flow 5hp turbine. STP-SCIII for T2 <br />may be dropping out at times & not able to controll turbine speed. Checked out with manager at kiosk. <br />01/16 Installed new FE Petro STP smart controller for T2. Reprogrammed and calibrated for master slave <br />configuration. FE Petro error code cleared all dispensers working correctly in service. FE Petro smart controller <br />provided by pilot. <br />01/18 Arrived onsite shut down Diesel to replace diesel turbine for diesel tank #2. Installed motor provided by pilot. <br />Diesel up working correctly. Will have site monitor for any slow flow issues. <br />01/22 Arrived onsite, checked in at kiosk. Checked in with manager. Performed troubleshooting on T2 & T3 slow <br />flow issues. Found T2 turbine lost sync with STP -SC III controller and not coming on properly. Corrected issue and <br />T2 operating normally noChanged out both MLLD's 99-LD2000 on T2 & T3 with New 99-LD2000E MLLD's�,l <br />Tested both to calibrate and working properly. Tested from leak detector back to turbine to verify check valved <br />operation and T2 holding at 17psi and T3 is holding at 15psi. Monitored fueling at Island and all working properly. <br />Checked out with manager at kiosk. <br />01/24 Arrived onsite and checked in at kiosk. Checked in with manager. Let him know the Diesel Island D21 - D30 <br />would be down approximately 3 hours. Performed troubleshooting on T2 and T3. Checked Ohm's, Amps, handle <br />hooks, leaking 2 stage valves, STP -SC III controller and performed non -precision line test from turbine ball valves in <br />T2 and T3 to the end of the lines. When checking 2 stage valves, 4 different dispensing points were leaking past <br />valve slightly but not continually flowing and not building back pressure rapidly. Changed controller T2 to Master and <br />T3 to Slave non -alternating. Supply voltage still low from breaker panel to anything connected to it. Still within STP - <br />SC III parameters. While still on site I was told D22 went into slow flow with no others dispensing, but no major <br />abnormalities in Amps on turbine power wiring at the same moment. Will need to escalate issues with Red Jacket <br />and Franklin Fueling support for a solution. Diesel Island D21 -D30 was down from 4:30pm-7:45pm. Checked out <br />with manager at kiosk. <br />01/25 Arrived onsite and checked in at kiosk. Checked in with manager. Checked on logged slow flows at site, <br />removed T2 and T3 Bio line and Diesel line screens. Cleaned out debris and reinstalled properly. No leaks. <br />Returned keys, checked out with manager at kiosk. <br />https://admin.servicefusion.com/printJobW ithoutRates?jobld=mDAy7—FOo5NJDGgjKeHmZJm—GWdxzi2pn DQ-CKOP—c 1/4 <br />