5/8/2018 0 Work Order #9607524 <br />01/30 Arrived onsite and checked in at kiosk, checked in with manager. Checked supply voltage at turbines and all <br />above 108volts per leg and 199volts or better per 2 legs. On STP -SC III controllers for T2 and T3 voltage coming in <br />and going out is at 108volts per leg & 202volts per two legs. Amps staying consistent on all at around 10.9amps. <br />Also when amps are going up from supply demand Slave controller is coming on properly. Site is running smoothly <br />today. Checked pressures on line & monitored & not going below 20psi today. Site let me know upon checkout 2 <br />slow flows had just happened back to back on D25 after i just stopped monitoring it while completing work order. <br />Checked D25 & not much fuel pressure pushing by 2 stage valves on master & kiosk. May have intermittent handle <br />hook problem but site will need to monitor further as troubleshooting is showing no problems. After further <br />discussion with the site D25 had a slow -flow as the rest of the people fueling on D21 -D30 line we're not affected by <br />this site said slow flow. This would be a meter or pulsar locking up a dispenser on the POS & NOT the same as a <br />product line slow flow we are troubleshooting on T2 & T3. This issue does not have the capability of discriminating <br />between fueling points. It would only affect all of them or none of them. Checked out with manager at kiosk. <br />02/01 Arrived onsite and checked into Kiosk. Met with Mike Wenzl, Isaac Garcia and James Blaine. We monitored <br />line pressure on D21-30 for 4 hours while inspecting line equipment and dispensers for leaks or valve/interlock <br />issues. All checked out but T2 check valve was not holding well. Pulled T2 turbine and replaced old check valve <br />with new one. Also cleaned expansion relief valve. Tested after repairs. Check pressure holding at 30psi. Will return <br />in morning to follow up. <br />02/02 Arrived onsite and checked into kiosk. Checked the issues report log and found no issues since yesterday <br />morning. Monitored line pressures for a while all looks real good. We encountered an event just as we were <br />checking out. Site reported a percieved slowflow on 6 dispensers at the same time. We were monitoring pressure <br />just before and no pressure issues. They did have a drive off on #30 at the same time of the issue report and we <br />repaired a broken breakaway supplied by site and tested/inspected for any leaks or damage. OK. Monitored <br />pressure and operation after drive off repairs and no more issues. Line pressure has been consistent and no <br />thermal contraction so far. <br />Note: Left 2 remaining turbine check valves onsite(In Bio -Shed). <br />Call being completed on PO#1831262-6040902 <br />Description <br />https://admin.servicefusion.com/pdntJobWithoutRates?jobld=mDAy7--FOo5NJDGgjKeHmZJm_GWdxzi2pnDQ-CKOP_c 2/4 <br />