My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2018-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 9:05:40 AM
Creation date
6/23/2020 6:57:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018-2019
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2018-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
256
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />SANAMUIN <br />COUNTY <br />Environmental Health Department <br />y 3 w <br />r ,... <br />Facility Name: <br />Facility Address: <br />Date: <br />FLYING J TRAVEL PLAZA #618* <br />1501 N JACK TONE RD, RIPON <br />May 03, 2018 <br />s <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br />Maintenance and monitoring records for the last three years were not found on site. The facility failed to document <br />the L8: diesel 2 annular setup data warning alarm that occurred on 4/13/2018. These records shall be maintained <br />on site for at least three years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) <br />monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) results of <br />sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, <br />ground water elevations, or other test results; (6) results of inventory readings and reconciliations. Immediately <br />locate and maintain all maintenance and monitoring records for the last three years on site and submit a statement <br />on how the alarm was addressed. <br />This is a minor violation. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class II. <br />206 <br />CCR 2712 Failure to comply with UST operating permit conditions. <br />Work orders from Jones Covey were found on site for maintenance work that was conducted on 12/5/2017, <br />1/22/2018, and 4/7/2018, which indicated that leak detectors and sensor were replaced. No notification were made <br />to EHD for these like for like replacements and the conditions for the no permit required work policy was not <br />followed. On 1/23/2018, Isaac Garcia contacted EHD about information regarding leak detector replacement and <br />EHD policy was submitted to him. No further correspondence was made. Emergency repairs relating to UST system <br />monitoring and release detection may be performed by a properly licensed, trained, and certified contractor <br />pursuant to the EHD's policy and a permit obtained within one business day from the EHD. All other repairs must <br />have a permit submitted to and approved by the EHD prior to beginning work. Immediately obtain a permit from the <br />EHD for the above mentioned repairs. A "failure to obtain a permit" penalty applies. Submit proof of correction to the <br />EHD. <br />This is a minor violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the December 2017 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: three L29: Disp 19 Satellite fuel alarms for 11/21/2017. During the monthly inspection, the <br />designated operator shall review the alarm history for the previous month, check that each alarm was documented <br />and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />FA0006672 PRO505264 SCO01 05/03/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.