My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BANNER
>
6437
>
2300 - Underground Storage Tank Program
>
PR0506004
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2024 4:20:39 PM
Creation date
6/23/2020 6:57:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0506004
PE
2361
FACILITY_ID
FA0007140
FACILITY_NAME
FLAG CITY SHELL*
STREET_NUMBER
6437
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532019
CURRENT_STATUS
01
SITE_LOCATION
6437 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506004_6437 W BANNER_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAK3JOAQUIN <br />COUNTY— <br />Environmental Health Department <br />FA0007140 PR0506004 SCO01 03/26/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue ( Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Underground (Storage TankaPlogramnspec#ionReport <br />Facility Name: <br />FLAG CITY SHELL* <br />Facility Address: <br />6437 W BANNER ST, LODI <br />Date: <br />March 26, 2018 <br />. .. , m.. <br />. UST System Observations <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />o V <br />❑ R <br />o COS <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V <br />o R <br />o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V <br />❑ R <br />o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V <br />o R <br />❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V <br />o R <br />o COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V <br />o R <br />o COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V <br />❑ R <br />o COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />o V <br />o R <br />o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V <br />o R <br />o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V <br />o R <br />o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V <br />o R <br />o COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V <br />o R <br />o COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />❑ V <br />o R <br />o COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V <br />o R <br />❑ COS <br />Single -Wald Ngn-Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V <br />o R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V <br />o R <br />o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1964) <br />o V <br />❑ R <br />o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V <br />o R <br />o COS <br />°Other Violations':® <br />2010 <br />See below <br />Unlisted General violation <br />❑ V <br />❑ R <br />❑ COS <br />� <br />S RWARY OF VIOLATIQNS . <br />(CLASS (;'CLASS ll , -o INOR - Notice to Comply] <br />Item # <br />Remarks <br />FA0007140 PR0506004 SCO01 03/26/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue ( Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.