Laserfiche WebLink
• <br />FA0007634 PRO506796 SCO01 10/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />U1dergroundt3torage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />ARCO AM PM #82602* <br />2430 JOE POMBO PKWY, TRACY <br />October 19, 2017 <br />�r.. <br />UST S§tem Observations y„ <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V o R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V ❑ R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V o R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />o V ❑ R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V o R ❑ COS <br />a. <br />.Single Walled Non -Pressurized Piping. <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />;r <br />�m Other viaations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below Unlisted Design/Construction violation <br />❑ V o R ❑ COS <br />77 SUMMARY OF VIOLATIONS <br />1, (CLASS I CLASS 11, or MINOR - Notice to Comply) L t <br />Item # <br />Remarks <br />101 <br />HSC 25284 No permit to operate. <br />A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit <br />for its operation has been issued by the local agency to the owner or operator of the UST system. Immediately <br />obtain a permit to operate a UST system from the EHD. An "Operating without a Permit' penalty applies. <br />This is a Class I violation. <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. For the tank TA0506797, the monitoring plan <br />indicates a 323 leak sensor but it was observed as 208. In all the tanks, in the monitoring plan section labeled <br />Record keeping, Tank integrity testing results was marked yes, but no results were found on site, and visual <br />inspection records was marked no in which records are observed on site, The monitoring plan must be uploaded to <br />the California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, <br />and submit for review by the EHD. <br />This was corrected on site. <br />This is a minor violation. <br />FA0007634 PRO506796 SCO01 10/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />