My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 3:10:02 PM
Creation date
6/23/2020 6:57:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ll <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />ARCO AM PM #82602* <br />2430 JOE POMBO PKWY, TRACY <br />October 19, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The 87 fill sump sensor was replaced and observed on <br />site from a 323 to a 208 sensor and the site map does not show the general layout of the piping. A site plan must be <br />submitted identifying the locations where monitoring will be performed. Immediately log into the California <br />Environmental Reporting System (CERS) at http-.Hcers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on 10/16/2016 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by 10/15/2016. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a Class II violation. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />302 <br />HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003). <br />The 87/91 split tank annular sensor failed to activate an audible and visual alarm when tested and, therefore, the <br />tank is not monitored. The interstitial space shall be monitored with a monitoring system connected to an audible <br />and visual alarm system. The sensor was replaced and retested during the inspection. A "UST Retrofit Verification <br />with Inspector Already Onsite" form has been completed and provided to the operator and contractor. The 409 <br />annular sensor was replaced 'like for like". <br />This was corrected on site. <br />This is a minor violation. <br />FA0007634 PR0506796 SCO01 10/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.