My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 3:10:02 PM
Creation date
6/23/2020 6:57:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />SWRCB, January 2002 Page of <br />Test Method Developed By: �7 UDC Manufacturer E Industry Standard x Professional Engineer <br />E Other (Spec) <br />Test Method Used: 0 Pressure E, Vacuum x Hydrostatic <br />D Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .0025 <br />UDC # 1&2 UDC # 3&4 <br />UDC # 5&6 <br />UDC # 7&8 <br />UDC Manufacturer: <br />Western Western <br />Western <br />Western <br />UDC Material: <br />FRP FRP <br />FRP <br />FRP <br />UDC Depth: <br />33" 33" <br />33" <br />33" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />81/2" 8 '/" <br />8 �" <br />11 <br />8 2 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />10" 10" <br />10" <br />7 ''/2" <br />Condition of UDC prior to <br />testing: <br />DRY DRY <br />DRY <br />DRY <br />Portion of UDC Tested' <br />Water Line 12" Water line 12" <br />Water Line 12" <br />Water Line 11" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />x Yes D No E NA x Yes 0 No E NA <br />x Yes E No a NA <br />x Yes 0 No ❑ NA <br />Turbine shutdown response time <br />5 seconds 5 seconds <br />6 seconds <br />7 seconds <br />Is system programmed for fail- <br />safe shutdown? <br />x Yes ❑ No © NA x Yes D No LENA <br />x Yes F No [INA <br />x Yes 0 No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />x Yes No U NA x Yes u No E NA <br />x Yes C No i � NA <br />x Yes ❑ No DNA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5 minutes 5 minutes <br />5 minutes <br />5 minutes <br />Test Start Time: <br />9:40 a.m. 9:50 a.m. <br />10:00 a.m. <br />10:45 a.m. <br />Initial Reading Ri): <br />.001 .001 <br />.001 <br />.001 <br />Test End Time: <br />10:10 a.m. 10:20 a.m. <br />10:30 a.m. <br />11:15 a.m. <br />Final Reading (RF): <br />.001 .001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes 30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-Ri): <br />0 0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes .005/30 Minutes <br />.005,30 Minutes <br />.005/30 Minutes <br />Test Result: <br />x Pass ❑ Fail x Pass ❑ Fail; <br />x Pass 12 Fail <br />x Pass 0 Fall <br />Was sensor removed for testing? <br />x Yes 0 No D NA x Yes Ej No —" NA <br />x Yes ❑ No E NA <br />x Yes E No U NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />x Yes ❑ No [INA x Yes .'-'No E NA <br />x Yes 0 No G NA <br />x Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing and recommended follow -t for failed tests) <br />, 9a. i i 6mP 9 <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.