My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 3:10:02 PM
Creation date
6/23/2020 6:57:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ll <br />SWRCB, January 2002 Page of <br />Facility is Not Equipped With Fill Riser Containment Sums 0 <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: 0 Sump Manufacturer E Industry Standard x Professional Engineer <br />❑ Other (Sped) <br />Test Method Used: 0 Pressure = Vacuum x Hydrostatic <br />0 Other (Spee) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .0025 <br />Fill Sump # T1:87 Fill Sump # T2:87 Fill Sump # T3:91 Fill Sump # T4 <br />Master Syphon PSumpiameter:01 42" 42'° 42„ <br />Sump Depth: <br />79" <br />77" 77" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />0" <br />0" 0" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />37" <br />37' 37 %2" <br />Condition of sump prior to <br />testing: <br />DRY <br />DRY DRY <br />Portion of Sump Tested <br />Water Line 39" <br />Water Line 39" Water Line 39 1/2" <br />Sump Material: <br />FRP <br />FRP FRP <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 minutes <br />10 minutes 10 minutes <br />Test Start Time: <br />3:00 pm. <br />3:50 p.m. 4:45 p.m. <br />Initial Reading (Rt): <br />.001 <br />.001 .001 <br />Test End Time: <br />3:30 p.m. <br />4:20 p.m. 5:15 p.m. <br />Final Reading (RF): <br />.001 <br />.001 .001 <br />Test Duration: <br />30 Minutes <br />30 Minutes 30 Minutes <br />Change in Reading (RF-Ri): <br />0 <br />0 0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes .005/30 Minutes <br />Test Results <br />x Pass ❑ Fail <br />x Pass" 0 Fain x Pass ❑ Fail <br />Pass ❑ Fall <br />Is there a sensor in the sump? <br />x Yes 0 No <br />x Yes 0 No x Yes ❑ No <br />Yes 0 No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />x Yes 0 No 0 NA <br />x Yes 0 No �.-- NA x Yes r No D NA <br />Yes . No DNA <br />Was sensor removed for testing? <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA x Yes 0 No 0 NA <br />Yes >0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after testing! <br />x Yes No n NA <br />x Yes ! � No NA x Yes - No 0 NA <br />Yes 0 No 0 NA <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />1QNMnf`t'AY III TFC <br />
The URL can be used to link to this page
Your browser does not support the video tag.