My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 11:25:26 AM
Creation date
6/23/2020 6:58:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />Page 4 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: <br />a <br />Sump Manufacturer <br />F-1 Industry Standard Professional Engineer <br />11 <br />Other (Specify) <br />Test Method Used: <br />a <br />Pressure <br />F Vacuum Hydrostatic <br />a <br />Other (Spec) <br />Test Equipment Used: vp 1 t <br />Equipment Resolution: +- . 0 0 2 " <br />Sump # 4 REG <br />Sump # 6 PRE <br />Sump # 5 MID <br />Sump # <br />rS:umpiameter: <br />7716111 <br />48" <br />48" <br />48"epth: <br />6111 <br />6111 <br />Sump Material: <br />fiberglass <br />fiberglass <br />fiberglass <br />Height from Tank Top to Top of <br />22" <br />22" <br />2211 <br />Highest Piping Pentration: <br />Height from Tank Top to Lowest <br />101F <br />1011 <br />1011 <br />Electrical Pentration: <br />Condition of sump prior to testing: <br />good <br />good <br />good <br />Portion of Sump Tested: 1 <br />2 4" <br />24" <br />24 F1 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />ayes aN�N <br />ayes ❑No❑N <br />ayes ❑N�N <br />Yes ❑No❑N <br />product and water)?* <br />Turbine shutdown response time: <br />2 - 5sec <br />2 - 5sec <br />2 - 5 s e c <br />Is system programmed for fail-safe <br />X Yes N N <br />a ❑ <br />---'Yes <br />X Yes N N <br />❑ � <br />X Yes N N <br />❑ ❑ `�� <br />X Yes No <br />� � <br />shutdown?* <br />�v <br />Was fail-safe verified to be <br />X Yes N N <br />❑ ^� <br />X Yes N N <br />❑ ❑ � <br />F77-1 <br />X YeS N N <br />❑ `� <br />X Yes NO <br />❑ <br />Operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5min <br />5min <br />5min <br />test: <br />Test Start Time: <br />11:20 <br />12:28 <br />12 : 4 5 <br />Initial Reading (Rl ): <br />0 <br />0 <br />0 <br />Test End Time: <br />11: 50 <br />12 : 5 8 <br />13: 15 <br />Final Reading (RF ): <br />-.00101, <br />-.0001" <br />-.00191, <br />Test Duration: <br />3 0mi n <br />3 0mi n <br />3 0mi n <br />Change in Reading (R F - RI ): <br />-.00101, <br />-.0001" <br />-.00191, <br />Pass/Fail Threshold or Criteria: <br />+-.00211 <br />+-. 0 0 2 " <br />+-.00211 <br />Was sensor removed for testing? <br />�Yes�NooNA X Yes No❑NA <br />oYesoNooNA <br />❑ Yes Noa <br />Was sensor properly replaced and❑ <br />X Ye N NA X Ye N NA <br />� ❑ � � <br />X Ye N NA <br />Yes N <br />❑ <br />verified functional after testing? <br />Comments - (include information on repairs made prior to testing, and recommended <br />follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.