Laserfiche WebLink
® <br />RECEIVED <br />SWRCB, January 2002 FEB Pag?412 <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />sTAil I H 1,04 A Is NVA <br />Test Method Developed By: r] UDC Manufacturer P-1 Industry Standard F-1 Prof <br />,M <br />r Other (Specify) <br />Test Method Used By: M Pressure � Vacuum F Hydrostatic <br />M Other S eci <br />=j <br />Test Equipment Used: VPLT <br />Equipment Resolution: 0.00001 in. <br />ll', <br />N ( <br />i1I�L16 <br />p,sai a <br />�. <br />,(1iri4i# <br />all o,,< <br />UDC Manufacturer: <br />environ <br />environ <br />environ <br />environ <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30.00 <br />30.00 <br />30.00 <br />30.00 <br />Height from UDC Bottom to Top <br />10.00 <br />10.00 <br />10.00 <br />10.00 <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />2.00 <br />2.00 <br />2.00 <br />2.00 <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />good <br />good <br />good <br />good <br />testing: <br />Portion of UDC Tested' <br />12 <br />12 <br />12 <br />12 <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />t t Yes 0 No 0 NA <br />r Yes r No P NA <br />r Yes r No r NA <br />G Yes C No r NA <br />product and water)?* <br />Turbine shutdown response time <br />02:00:00 sec <br />02:00:00 see <br />02:00:00 sec <br />02:00:00 sec <br />Is system programmed for fail- <br />r Yes r No rg NA <br />ro Yes r No f ' NA <br />r Yes rh No 0, NA <br />Yes (7 No f"' NA <br />safe shutdown?* <br />Was fail-safe verified to be <br />(x Yes P No ro NA <br />r Yes r No r NA <br />f+' Yes 11 No P NA <br />G Yes O No 4,i NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />5 min <br />5 min <br />5 min <br />5 min <br />starting test <br />Test Start Time: <br />11:08:00 <br />11:57:00 <br />11:57:00 <br />10:42:00 <br />Initial Reading (Rt): <br />0.00000 in. <br />0.00000 in. <br />0.00000 in. <br />0.00000 in. <br />Test End Time: <br />11:23:00 <br />12:12:00 <br />12:12:00 <br />10:57:00 <br />Final Reading (RF): <br />-0.00040 in. <br />-0.00050 in. <br />-0.00130 in. <br />0.00150 in. <br />Test Duration: <br />15 min <br />15 min <br />15 min <br />15 min <br />Change in Reading (Rg-RI) : <br />-0.00040 in. <br />-0.00050 in. <br />-0.00130 in. <br />0.00150 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />�2g F <br />F� r <br />i r£ijy��R <br />' <br />Was sensor removed for testing? <br />P Yes ro No P NA <br />(+''= Yes r No 1" NA <br />0 Yes No G NA <br />Q YesII Nor NA <br />Was sensor properly replaced and <br />0 Yes Gip No NA <br />r Yes r Nor NA <br />G Yes ri No r NA <br />0 Yes rl No P NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is 'NO" or "NA", the entire UDC must <br />be tested. <br />WO: 2326766 <br />