My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:. .$)gov.o <br /> a <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON#208117* 1755 S TRACY BLVD,TRACY February 23,2015 <br /> UST systbm Observations <br /> 323 CCR 2636(0(2) Leak detector failed to detect a 3.0 gph leak at 10 psi o V a R o COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty o V o R a COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of rive gallons ❑V o R o COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements o V o R a COS <br /> 327 NSC 25283.5 Unburied below grade UST fair to meet exemption status o V o R o COS <br /> 326 CCR 2717.1(g) Tampered with red tag _ ❑V o R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST a V ❑R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms a V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored a V ❑R o COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements o V a R a COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements a V o R o COS <br /> i Non-Pressurized Piping <br /> i <br /> 401 CCR 2636(x)(3) Suction piping not property sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 26430 Daily monitoring of suction pipe(pre-Jan 1984)not pefforrned a V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) a V o R o COS <br /> i t <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1 ) a V o R o COS <br /> Other Violations <br /> R 2010 See below Unlisted Administration/Documentation violation a V a R a COS <br /> I 2030 See below Unlisted Operations/Maintenance violation a V ❑R ❑COS c <br /> 2060 See glow Unlisted Design/Construction violation a V a R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLA68 t,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring and response plans are not current and/or not approved by the EHD. The monitoring plan requests <br /> the"Name of First Person Having Responsibility"and"Name of Second Person Having Responsibility". The <br /> response plan requests the"Name"of responsible persons. All of these sections are filled in with a title or a general <br /> contact company, but no names. The monitoring and response plans must be uploaded to the California e <br /> Environmental Reporting System(CERS), Immediately log into CERS, make the necessary changes,and submit € <br /> for review by the EHD. Ensure a copy is available for inspection at any time. This is a repeat violation,Class II <br /> t <br /> i <br /> Received rtrePhone: , <br /> STACY RIVERA,Senior REHS --- (209}468-3 0 02/23/2015 <br /> i <br /> Page 3 of 5 <br /> 3 <br /> t <br /> I <br /> P <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.