My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> ( <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue,Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web: siaov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON 208117*a 1755 S TRACY BLVD,TRACY February 23, 2015 <br /> SUMMARY OF VIOLATIONS <br /> {CLASS 1,GLASS 11,or MINOR Notice to Comply) <br /> ' l <br /> Itern# Remarks <br /> 201 CCR 2712(b)Failed to maintain alarm logs and/or records of follow up actions. t <br /> Maintenance and monitoring records for the last three years were not found on site. No work orders were found for <br /> the leak detector testing conducted on March 7,2014. The testing was noted in the March 2014 designated r <br /> operator monthly inspection report, but no work orders were attached to the report. These records shall be <br /> maintained on site for at least three years, Monitoring records include: (1)date and time of all monitoring or <br /> sampling, (2)monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field;(5) logs of all readings of gauges or other monitoring <br /> equipment, ground water elevations, or other test results;(6)results of inventory readings and reconciliations. The <br /> missing work order was located by Ms. Evans,and a copy was placed on site at the time of inspection. This is a <br /> minor violation. This was corrected on site. <br /> 308 CCR 2636(f)Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The 87 fill sump sensor failed to activate an audible and visual alarm when tested to ensure continuous monitoring <br /> of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the <br /> flow of product at the dispenser when it detects a leak. The sensor was replaced and retested during the <br /> inspection. A"UST Retrofit Verification with Inspector Already Onsite"form has been completed and provided to the <br /> operator and contractor. This is a minor violation. This was corrected on site. <br /> 0 <br /> E <br /> Overall Inspection : <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 25, 2015 <br /> Ar6*etq Dam, 4W09 ImW <br /> Consent to perform the inspection,take photos and collect samples was given by [NAME AND TITLE] . This <br /> facility's designated operator is Elijah Pendergra (ICC expiration date 6/2/16) . The service technician was r <br /> Jarrod Cooke(ICC expiration date,4/30/15 ),who had the following manufacturer's certifications., Veeder Root x <br /> 5/6/16. <br /> **The technician did not have a VMI certification available. Per Mr, Cooke, he recently took the test and has not <br /> received his copy of the certification for the leak detector tester(LDT-5000). A copy of this certification current for <br /> today's date must be submitted to the EH . If this certification is not received, the leak detector testing will need <br /> to be redone by a certified technician <br /> Note: The 91 spill bucket did not pass initial testing. The technician replaced the drain valve at the time of <br /> inspection. The spill bucket was retested and passed. <br /> Note: The cord on the 91 annular wraparound sensor was found to be too short,with no excess for removing the <br /> sensor for testing There were no records found, either in EHD files or in the facility work orders and repair logs, <br /> indicating any work was done with this annular sensor since the last inspection on 3/3/14. Additional cording was ` <br /> added at the time of inspection. <br /> Note: The 87 tank form was left blank for"vent piping transition sump". This section should be marked as 'none', <br /> Recelvep by ndha : ��STACY <br /> napector: one ate: <br /> RIVERA, Senior REHS 1(209)468-3440 02/23/2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.