My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:04:02 PM
Creation date
6/23/2020 6:58:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0508452
PE
2361
FACILITY_ID
FA0007787
FACILITY_NAME
PACIFIC CAR WASH/MARKETPLACE INC
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
01
SITE_LOCATION
4405 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508452_4405 PACIFIC_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.segov.org/ehd <br />Underground Storage Tank Pr©grarn Inspection Report <br />Facility Name: <br />PACIFIC CAR WAST-YMARKETPLACE INC <br />Facility Address: <br />4405 PACIFIC AVE, STOCKTON <br />Date: <br />May 08, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS`I, CLASS 11, or MINOR-- Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br />where monitoring will be performed. Include the locations of the line leak detectors. Immediately log into the <br />California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST <br />Monitoring Site Plan. <br />This is a minor violation. <br />110 <br />CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br />Secondary containment testing was performed on May 12, 2016 and a test report was submitted on August 22, <br />2016, greater than two months late. A copy of the test report must be submitted within 30 days of the tests. Take <br />all necessary precautions to ensure testing and submittal of test reports are performed in a timely manner. <br />This is a minor violation. <br />204 <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />205 <br />CCR 2712(i) Failure to have an approved UST response plan available onsite. <br />An approved copy of the Response Plan was not available for inspection. A copy of the Response Plan shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the Secondary Containment testing on <br />the June 29, 2016 through April 26, 2017 designated operator monthly inspection reports. The designated operator <br />inadvertently entered 5/23/16 on all of the designated operator monthly inspection reports instead of the correct <br />date, 5/12/16. During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. Ensure that <br />designated operators performing monthly inspections at this facility are including all of the required information on <br />the reports. <br />This is a minor violation. <br />FA0007787 PR0508452 SCO01 05/08/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.