My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:47:40 PM
Creation date
6/23/2020 6:59:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\15237\PR0517272\FINAL JUDGMENT ON CONSENT 09-29-08.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
420
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 13 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: UDC Manufacturer F-1 Industry Standard ❑X Professional Engineer <br /> Other (Specify) <br /> Test Method Used: FI Pressure F Vacuum Hydrostatic <br /> El Other (Specify) <br /> Test Equipment Used: vpl t Equipment Resolution: vplt to gph <br /> UDC# 16/17 UDC# 18 UDC# 19 UDC# 19sat <br /> UDC Manufacturer: W•f. W.f. W.f. W.f. <br /> UDC Material: fiberglass fiberglass fiberglass fiberglass <br /> UDC Depth: 3111 3111 311f 3111 <br /> Height from UDC Top to Top of 9 to 911 9" 911 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 1/211 1/2'1 1/211 1/2'1 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested: 1 111, 1111 111, 1111 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X❑Yes E Yes_NoDN Yes MNo❑N M Yes F]No[:]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec 2-5sec 2-5 s e c <br /> Is system programmed for fail-safe ❑ � ❑ ❑ � ❑ '---'Yes <br /> ❑ <br /> shutdown?* X Yes N N X Yes N N X Yes N N X Yes No <br /> Was fail-safe verified to be Yes❑No❑N Yes❑N�N Yes❑No�N Yes�No�N <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and starting SMIN 5MIN 5MIN 5MIN <br /> test: <br /> Test Start Time: 10:57 10:55 8 :34 8:3 0 <br /> Initial Reading(Ri): 2 .132 5.754 8.358 4.702 <br /> Test End Time: 10 :59 11:10 8:4 9 8:45 <br /> Final Reading(RF): -13.000 5.754 8.358 4.702 <br /> Test Duration: 2min 15min 15min 15min <br /> Change in Reading(RF-R1 ): 1.8gph .000gph .000gph .000gph <br /> Pass/Fail Threshold or Criteria: .05gph .05gph 05gph .05gph <br /> Was sensor removed for testing? Yes❑No❑NAYes NA Yes ]No❑NA X Yes No[]N <br /> Was sensor properly replaced and ❑ � � � MyeC]NcONA <br /> ❑ ❑verified functional after testing? N NA X Ye N NA X yes N <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer toanyof the questions indicated with an <br /> asterisk(*)is"NO" or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.